Suppr超能文献

通过玻璃体荧光光度测定法对糖尿病视网膜病变早期阶段的特征描述。

Characterization of the early stages of diabetic retinopathy by vitreous fluorophotometry.

作者信息

Cunha-Vaz J G, Gray J R, Zeimer R C, Mota M C, Ishimoto B M, Leite E

出版信息

Diabetes. 1985 Jan;34(1):53-9. doi: 10.2337/diab.34.1.53.

Abstract

We compared insulin-dependent diabetic patients with minimal (16 eyes of 9 patients) or no retinopathy (45 eyes of 27 patients) to normal volunteers (20 eyes of 12 subjects) using a commercial vitreous fluorophotometer and different procedures for artifact correction. The influence of background autofluorescence was minimized through the use of a software program that subtracted a fluorophotometric scan obtained before administration of fluorescein from that obtained after its injection. We also compared two programs designed to minimize the contribution of the chorioretinal peak spread function to the readings in the vitreous. The fluorescein concentration in the posterior vitreous was then averaged within two different regions. We then assessed the influence of these data-processing methods on the spread of the results of the different groups. The clinical study showed that only the posterior vitreous concentration of fluorescein is relevant in the evaluation of the blood-retinal barrier. However, since there is a gradient of fluorescein concentration in the posterior vitreous, one needs a scanning device so that one can measure at a precise location in front of the retina. The posterior vitreous concentration of fluorescein was significantly increased in diabetic subjects with one or no aneurysms as compared with normals. Moreover, the eyes with minimal retinopathy, as judged by the presence of microaneurysms, had higher values than those without retinopathy. The clear differences among these three groups were not present when the midvitreous values were used.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

我们使用商用玻璃体荧光光度计和不同的伪影校正程序,将患有轻度(9例患者的16只眼)或无视网膜病变(27例患者的45只眼)的胰岛素依赖型糖尿病患者与正常志愿者(12名受试者的20只眼)进行比较。通过使用一个软件程序,将荧光素注射后获得的荧光光度扫描结果减去注射前获得的扫描结果,从而将背景自发荧光的影响降至最低。我们还比较了两个旨在将脉络膜视网膜峰值扩散函数对玻璃体读数的影响降至最低的程序。然后在两个不同区域内对玻璃体后部的荧光素浓度进行平均。接着,我们评估了这些数据处理方法对不同组结果离散度的影响。临床研究表明,在评估血视网膜屏障时,只有玻璃体后部的荧光素浓度是相关的。然而,由于玻璃体后部存在荧光素浓度梯度,因此需要一种扫描设备,以便能够在视网膜前方的精确位置进行测量。与正常人相比,患有一个或没有动脉瘤的糖尿病患者玻璃体后部的荧光素浓度显著升高。此外,根据微动脉瘤的存在判断为轻度视网膜病变的眼睛,其荧光素浓度值高于无视网膜病变的眼睛。当使用玻璃体中部的值时,这三组之间没有明显差异。(摘要截短至250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验