Suppr超能文献

尽管血小板添加剂溶液SSP+和T-PAS+在成分和增塑剂方面存在差异,但它们在储存血小板浓缩物时可互换使用。

Platelet Additive Solutions SSP+ and T-PAS+ Are Interchangeable for Platelet Concentrate Storage despite Differences in Composition and Plasticizer.

作者信息

Van Aelst Britt, Bens Karen, Sabot Bea, Vertongen Sarah, Feys Hendrik B, Compernolle Veerle, Six Katrijn R

机构信息

Blood Services, Belgian Red Cross Flanders, Mechelen, Belgium.

Transfusion Research Center, Belgian Red Cross Flanders, Ghent, Belgium.

出版信息

Transfus Med Hemother. 2024 Mar 26;51(6):424-429. doi: 10.1159/000538003. eCollection 2024 Dec.

Abstract

INTRODUCTION

Platelet additive solutions support ex vivo storage of platelet concentrates used for transfusion. The composition of platelet additive solutions within one generation (i.e., PAS-E) is similar but not identical. Additionally, the platelet additive solution storage bag may contain different plasticizers. This study compares the effect of two PAS-E solutions (SSP+ vs. T-PAS+, stored in a DEHP-containing and DEHP-free bag, respectively) to investigate if both additive solutions are interchangeable for platelet concentrate storage.

METHODS

Platelet concentrates stored in plasma supplemented with SSP+ or T-PAS+ were compared by using a pool-and-split design. Platelet metabolism was investigated using a blood gas analyzer. The degree of platelet storage lesion was determined by flow cytometry to measure granule release and phosphatidylserine scrambling.

RESULTS

The quality of platelet concentrates stored in either SSP+ or T-PAS+ is acceptable as pH decreased only slightly as a function of time. PH remained above 7.2 on exiration day +1 (day 6), which is far above the minimal criterion of 6.4. Platelet storage lesion was comparable between the two study groups with only limited α-granule release and phosphatidylserine surface expression in both groups after storage for 5 days, = 0.547 and = 0.825, respectively.

CONCLUSION

This study supports a safe switch between SSP+ and T-PAS+ storage solutions for platelet concentrates despite slight differences in storage solution composition and DEHP content.

摘要

引言

血小板添加剂溶液可支持用于输血的血小板浓缩物的体外储存。同一代内的血小板添加剂溶液(即PAS-E)组成相似但并不完全相同。此外,血小板添加剂溶液储存袋可能含有不同的增塑剂。本研究比较了两种PAS-E溶液(分别为SSP+和T-PAS+,分别储存在含邻苯二甲酸二(2-乙基己基)酯和不含邻苯二甲酸二(2-乙基己基)酯的袋子中)的效果,以研究这两种添加剂溶液在储存血小板浓缩物时是否可互换。

方法

采用混合分割设计比较储存在补充有SSP+或T-PAS+的血浆中的血小板浓缩物。使用血气分析仪研究血小板代谢。通过流式细胞术测定血小板储存损伤程度,以测量颗粒释放和磷脂酰丝氨酸外翻。

结果

储存在SSP+或T-PAS+中的血小板浓缩物质量是可接受的,因为pH值仅随时间略有下降。在有效期第1天(第6天)时pH值仍高于7.2,远高于最低标准6.4。两个研究组之间的血小板储存损伤相当,储存5天后两组仅出现有限的α颗粒释放和磷脂酰丝氨酸表面表达,分别为P = 0.547和P = 0.825。

结论

本研究支持在SSP+和T-PAS+储存溶液之间安全切换用于血小板浓缩物,尽管储存溶液组成和邻苯二甲酸二(2-乙基己基)酯含量存在细微差异。