Mounir Amr, Awny Islam, Amer Ibrahim, Mahmoud Alaa, Mossa Elshimaa AMateen
Ophthalmology Department, Faculty of Medicine, Sohag University, Almohafza St. Mailbox: 82511, Sohag, 82511, Egypt.
Ophthalmology Department, Faculty of Medicine, Al-Azhar University, Assiut, Egypt.
BMC Ophthalmol. 2024 Dec 20;24(1):543. doi: 10.1186/s12886-024-03796-w.
To evaluate the clinical outcomes of implanting two symmetrical Kerarings via a femtosecond laser in grade three keratoconus.
This was a retrospective nonrandomized controlled clinical study. The study included one eye from each of twenty-three patients, all with Grade 3 keratoconus as classified by the Amsler-Krumeich classification. The ICRS surgery was performed with the patient under topical anaesthesia (benoxinate hydrochloride 4 mg/mL 0.4%). A tunnel channel was created by a femtosecond laser using a 60-kHz infrared neodymium glass femtosecond laser at a wavelength of 1053 nm (Abbott Laboratories Inc., Abbott Park, Illinois, USA). Two symmetrical Kerarings (Mediphacos Inc., Belo Horizonte, Brazil) were implanted in all the cases with 160° arcs and 250,300 µm thicknesses according to the corneal thickness at the implantation site. After surgery, the patients underwent a full ocular evaluation on Days 1, 7, and 14 and after one month. For a period of 1 year, corneal topography readings were taken quarterly, and the numbers of Pentacam measurements were averaged.
Twenty-three eyes of twenty-three patients were included in this study. The mean value (± SD) of age was 22.8 (± 6.84) years. Six (26.09%) eyes were from males, and 17 (73.91%) were from females. The cone location was central for all patients. Spherical error, cylindrical error, spherical equivalent (SE), uncorrected visual acuity (UCVA), and best corrected visual acuity (BCVA) significantly improved after 3, 6, 9, and 12 months compared with the preoperative values (P value < 0.001). There was no significant difference in the axial and pachymetry readings before and after surgery. Kmax flattened insignificantly at 3 and 6 months of follow-up, whereas significant flattening was achieved at 9 and 12 months (P values = 0.046 and 0.042, respectively). The K mean, K1, K2, anterior elevation, topographic cylinder, and Q value posterior to the corneal surface were significantly lower at the 3-, 6-, 9- and 12-month follow-up visits than preoperatively (P value < 0.05). Posterior elevation and the Q value of the anterior corneal surface were significantly greater after surgery (3, 6, 9, and 12 months) than before surgery (P value < 0.05). With respect to the Belin ABCD grading system, A and D significantly improved throughout the follow-up visits (3, 6, 9, and 12 months) (P value < 0.001), whereas B and C did not significantly differ between the 3-, 6-, 9- and 12-month follow-up visits and the preoperative values.
Grade 3 KC, with the central cone managed with two symmetrical kera-rings, showed favourable results with respect to clinical and topographic outcomes, with improvements in the ABCD staging system of KC.
评估通过飞秒激光植入两枚对称的角膜基质环(Kerarings)治疗Ⅲ期圆锥角膜的临床效果。
这是一项回顾性非随机对照临床研究。研究纳入了23例患者的单眼,所有患者均为Amsler-Krumeich分类法中的Ⅲ期圆锥角膜。ICRS手术在表面麻醉(4mg/mL盐酸丁氧普鲁卡因0.4%)下进行。使用波长为1053nm的60kHz红外钕玻璃飞秒激光(美国伊利诺伊州阿伯特帕克市雅培实验室公司)制作隧道通道。根据植入部位的角膜厚度,为所有病例植入两枚对称的角膜基质环(巴西贝洛奥里藏特市Mediphacos公司),弧长160°,厚度250、300μm。术后,患者在第1天、第7天、第14天和1个月后接受全面的眼部评估。在1年的时间里,每季度进行角膜地形图测量,并对Pentacam测量值求平均值。
本研究纳入了23例患者的23只眼。年龄的平均值(±标准差)为22.8(±6.84)岁。6只(26.09%)眼为男性,17只(73.91%)眼为女性。所有患者的圆锥位置均在中央。与术前值相比,术后3、6、9和12个月时,球镜度数、柱镜度数、等效球镜度数(SE)、未矫正视力(UCVA)和最佳矫正视力(BCVA)均显著改善(P值<0.001)。手术前后的眼轴和角膜厚度测量值无显著差异。随访3个月和6个月时,最大角膜曲率(Kmax)无明显变平,而在9个月和12个月时出现显著变平(P值分别为0.046和0.042)。随访3、6、9和12个月时,角膜平均曲率(Kmean)、K1、K2、前表面高度、地形图柱镜度数和角膜后表面Q值均显著低于术前(P值<0.05)。术后(3、6、9和12个月)角膜后表面高度和前表面Q值显著高于术前(P值<0.05)。根据贝林ABCD分级系统,随访期间(3、6、9和12个月)A和D显著改善(P值<0.001),而B和C在随访3、6、9和12个月时与术前值无显著差异。
Ⅲ期圆锥角膜采用两枚对称的角膜基质环治疗中央圆锥,在临床和地形图结果方面显示出良好效果,圆锥角膜的ABCD分期系统有所改善。