Shen Xingqian, Pan Hui, Wang Linlin, Xie Wen, Leng Yangming, Liu Bo, Xiao Hongjun
Department of Otorhinolaryngology-Head and Neck Surgery, Tongji Medical College, Union Hospital, Huazhong University of Science and Technology, Wuhan, China.
Front Neurol. 2024 Dec 18;15:1406617. doi: 10.3389/fneur.2024.1406617. eCollection 2024.
The pathological hallmark of Ménière's disease is endolymphatic hydrops, which can lead to an increase in basilar membrane stiffness and, consequently, an acceleration of the traveling wave of sound. The cochlear hydrops analysis masking procedure (CHAMP), which is an auditory brainstem response test masked at various frequencies with high-pass noise masking, uses the principle of the traveling wave velocity theory to determine the presence of endolymphatic hydrops.
This study aimed to review the previous results of the CHAMP, expound the principles and key indicators, and discuss its clinical significance in diagnosing Ménière's disease.
A narrative review was performed to revisit the principles of the CHAMP test, procedures, and clinical application results in diagnosing Ménière's disease.
According to the published literature, the CHAMP has a specificity of 31-100%, a sensitivity of 28-100%, and a diagnostic accuracy of 30-100% for the diagnosis of Ménière's disease, including patients with definite, probable, or possible Ménière's disease in various studies. These inconsistent results were due to subject inclusion criteria, variable settings, waveform identification, and other factors. Nevertheless, as an electrophysiological technique, the CHAMP may have a relatively high diagnostic value in patients with a definite Ménière's disease.
The CHAMP is still potentially useful for studying the pathophysiology of hydropic ear diseases since the procedure can measure the traveling wave velocity of the basilar membrane in the era of imaging to detect endolymphatic hydrops for Ménière's disease.
梅尼埃病的病理标志是内淋巴积水,这会导致基底膜硬度增加,进而加速声音的行波。耳蜗积水分析掩蔽程序(CHAMP)是一种听觉脑干反应测试,通过高通噪声掩蔽在不同频率下进行掩蔽,利用行波速度理论来确定内淋巴积水的存在。
本研究旨在回顾CHAMP的既往结果,阐述其原理和关键指标,并讨论其在梅尼埃病诊断中的临床意义。
进行叙述性综述,以重新审视CHAMP测试的原理、程序以及在梅尼埃病诊断中的临床应用结果。
根据已发表的文献,CHAMP对梅尼埃病诊断的特异性为31%-100%,敏感性为28%-100%,诊断准确性为30%-100%,其中包括各项研究中明确、可能或疑似梅尼埃病的患者。这些不一致的结果归因于受试者纳入标准、变量设置、波形识别等因素。然而,作为一种电生理技术,CHAMP在明确诊断为梅尼埃病的患者中可能具有较高的诊断价值。
CHAMP在研究积水性耳病的病理生理学方面仍具有潜在价值,因为该程序能够在成像时代测量基底膜的行波速度,以检测梅尼埃病的内淋巴积水。