• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Design optimization of a 1-D array of stemless plastic scintillation detectors.

作者信息

Aynehband Samaneh, Hill Ian G, Syme Alasdair

机构信息

Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada.

Department of Radiation Oncology, Dalhousie University, Halifax, Nova Scotia, Canada.

出版信息

Med Phys. 2025 Apr;52(4):2560-2569. doi: 10.1002/mp.17608. Epub 2025 Jan 6.

DOI:10.1002/mp.17608
PMID:39762714
Abstract

BACKGROUND

A stemless plastic scintillation detector (SPSD) is composed of an organic plastic scintillator coupled to an organic photodiode. Previous research has shown that SPSDs are ideally suited to challenging dosimetry measurements such as output factors and profiles in small fields. Lacking from the current literature is a systematic effort to optimize the performance of the photodiode component of the detector. An optimized detector could permit a reduction in detector element size, thus improving spatial resolution without degradation of the signal to noise ratio values seen previously.

PURPOSE

SPSDs use an organic photodiode coupled to a plastic scintillator to measure ionizing radiation fields. The design retains the benefits of plastic scintillation detectors (energy and dose rate independence, no perturbation factors, etc.) but avoids the challenges of optical fiber-based systems (Cerenkov radiation). In this work, the design of a 1-dimensional array of SPSDs is optimized to maximize the measured signal.

METHODS

ITO-covered PET was etched using hydrochloric acid, and the substrate was cleaned.

PEDOT

PSS and P3HT: PCBM (different weight ratios) were then applied to the substrate using spin-coating. Finally, aluminum top electrodes were added using vacuum thermal evaporation to complete the fabrication process. The variables studied for the optimization included: spin coater's speed (i.e., film thickness), P3HT: PCBM ratio, solution concentration, and scintillator coating.

RESULTS

Increasing the film thickness from ∼80 nm to ∼138 nm increased the measured signal by a factor of approximately 7.7. Changing the ratio of P3HT to PCBM from (1:1) to (4:1) resulted in approximately 3.5 times higher signal. Additionally, increasing the total concentration of the solution from 2% to 4% by weight ratio increased the signal by roughly a factor of 2.5 for a P3HT: PCBM ratio of 2:1. However, for a P3HT: PCBM ratio of 4:1, increased solution concentration reduced measured signals to approximately 1.7 times lower than normal concentration. Covering the air gaps of the etched scintillator with white paint resulted in a signal increase of about 2.2 times higher compared to black paint.

CONCLUSION

An optimization process was conducted to improve the signal output of the radiation detector, which consisted of a 1-dimensional photodiode array combined with a scintillator. This approach has resulted in a sensitivity increase of about 24 times compared to the original sample prior to optimizing the fabrication parameters and scintillator's properties (∼0.02 nC/cGy vs. ∼0.5 nC/cGy). The most efficient device was found to have a weight ratio of (2:1) P3HT: PCBM and a total solution concentration of 4%. Additionally, using a scintillator painted white was found to produce superior outcomes compared to black paint.

摘要

相似文献

1
Design optimization of a 1-D array of stemless plastic scintillation detectors.
Med Phys. 2025 Apr;52(4):2560-2569. doi: 10.1002/mp.17608. Epub 2025 Jan 6.
2
Fabrication and characterization of a stemless plastic scintillation detector.无柄塑料闪烁探测器的制造与特性研究
Med Phys. 2020 Nov;47(11):5882-5889. doi: 10.1002/mp.14475. Epub 2020 Oct 6.
3
Measuring small field profiles and output factors with a stemless plastic scintillator array.使用无柄塑料闪烁体阵列测量小射野分布和输出因子。
Med Phys. 2022 Jan;49(1):624-631. doi: 10.1002/mp.15357. Epub 2021 Dec 16.
4
Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy.优化多点塑料闪烁体剂量计用于高剂量率近距离治疗。
Med Phys. 2019 May;46(5):2412-2421. doi: 10.1002/mp.13498. Epub 2019 Apr 2.
5
Characterization of the plastic scintillation detector Exradin W2 for small field dosimetry.用于小野剂量学的塑料闪烁探测器 Exradin W2 的特性描述。
Med Phys. 2019 May;46(5):2468-2476. doi: 10.1002/mp.13501. Epub 2019 Apr 8.
6
Performance of long rectangular semi-monolithic scintillator PET detectors.长矩形半整体闪烁体 PET 探测器的性能。
Med Phys. 2019 Apr;46(4):1608-1619. doi: 10.1002/mp.13432. Epub 2019 Feb 20.
7
Use of water-equivalent plastic scintillator for intravascular brachytherapy dosimetry.水等效塑料闪烁体在血管内近距离放射治疗剂量测定中的应用。
Australas Phys Eng Sci Med. 2004 Mar;27(1):5-10. doi: 10.1007/BF03178881.
8
Cerenkov free micro-dosimetry in small-field radiation therapy technique.切伦科夫自由微剂量学在小野放疗技术中的应用。
Phys Med Biol. 2024 Jun 12;69(12). doi: 10.1088/1361-6560/ad51c6.
9
Characterizing the response of miniature scintillation detectors when irradiated with proton beams.表征微型闪烁探测器在质子束辐照下的响应。
Phys Med Biol. 2008 Apr 7;53(7):1865-76. doi: 10.1088/0031-9155/53/7/004. Epub 2008 Mar 10.
10
Plastic scintillation dosimetry: optimal selection of scintillating fibers and scintillators.塑料闪烁剂量测定法:闪烁纤维与闪烁体的优化选择
Med Phys. 2005 Jul;32(7):2271-8. doi: 10.1118/1.1943807.