Suppr超能文献

经典布鲁斯托恩九步充气/放气鼓室声导抗咽鼓管功能测试正常值的建立。

Establishment of the Normative Value of Classical Bluestone's Nine-Step Inflation/Deflation Tympanometric Eustachian Tube Function Test.

作者信息

Wang Jing-Jie, Jiang Rong-San, Weng Chien-Hsiang

机构信息

Department of Otolaryngology, Taichung Veterans General Hospital, Taichung 40705, Taiwan.

School of Medicine, National Yang Ming Chiao Tung University, Taipei 112304, Taiwan.

出版信息

Diagnostics (Basel). 2024 Dec 13;14(24):2810. doi: 10.3390/diagnostics14242810.

Abstract

BACKGROUND/OBJECTIVES: The nine-step inflation/deflation tympanometric Eustachian tube function test (commonly referred to as the nine-step test) is a widely utilized method for evaluating Eustachian tube function (ETF). This study aimed to establish normative values for the nine-step test to facilitate the diagnosis of Eustachian tube dysfunction (ETD).

METHODS

A total of 160 adults, including 70 healthy volunteers and 90 patients with chronic rhinosinusitis (CRS), were recruited for this study. Participants were further categorized into "fair ETF" and "poor ETF" groups based on their scores on the Eustachian Tube Dysfunction Questionnaire (ETDQ-7). Eustachian tube function was assessed using both the nine-step test and the ETDQ-7. The diagnostic accuracy of the maximal peak pressure difference (MPD) from the nine-step test was evaluated, using an ETDQ-7 score of ≥14 as the reference standard. Discriminative ability was analyzed using receiver operating characteristic (ROC) curves.

RESULTS

An MPD value of ≤4 yielded an area under the ROC curve (AUC) of 0.619, indicating moderate discriminative ability in the Taiwanese population. The median MPD value on the nine-step test was 9.5 (interquartile range [IQR]: 4.5-14.0) in participants with an ETDQ-7 score of <14, compared to a median MPD value of 7.5 (IQR: 2.5-12.0) in those with an ETDQ-7 score of ≥14 ( = 0.033). This finding suggests a potential association between MPD values and ETDQ-7 scores.

CONCLUSIONS

This study identified an MPD value of 4 as a normative cutoff for screening ETD in a Taiwanese population. However, the diagnostic discriminative power of this parameter was moderate.

摘要

背景/目的:九步式鼓膜测压法咽鼓管功能测试(通常称为九步测试)是一种广泛用于评估咽鼓管功能(ETF)的方法。本研究旨在建立九步测试的正常参考值,以促进咽鼓管功能障碍(ETD)的诊断。

方法

本研究共招募了160名成年人,其中包括70名健康志愿者和90名慢性鼻窦炎(CRS)患者。根据他们在咽鼓管功能障碍问卷(ETDQ-7)上的得分,参与者被进一步分为“良好ETF”和“较差ETF”组。使用九步测试和ETDQ-7评估咽鼓管功能。以ETDQ-7得分≥14作为参考标准,评估九步测试中最大峰值压差(MPD)的诊断准确性。使用受试者工作特征(ROC)曲线分析判别能力。

结果

MPD值≤4时,ROC曲线下面积(AUC)为0.619,表明在台湾人群中具有中等判别能力。在ETDQ-7得分<14的参与者中,九步测试的MPD值中位数为9.5(四分位间距[IQR]:4.5-14.0),而在ETDQ-7得分≥14的参与者中,MPD值中位数为7.5(IQR:2.5-12.0)(P = 0.033)。这一发现表明MPD值与ETDQ-7得分之间可能存在关联。

结论

本研究确定MPD值为4作为台湾人群中筛查ETD的正常临界值。然而,该参数的诊断判别力中等。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c81e/11674683/46d8a6af9f4f/diagnostics-14-02810-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验