Suppr超能文献

使用百泰克公司MxP QUANT 500检测法评估人乳的代谢谱。

Evaluating Metabolic Profiling of Human Milk Using Biocrates MxP QUANT 500 Assay.

作者信息

Hampel Daniela, Shahab-Ferdows Setareh, Kac Gilberto, Allen Lindsay H

机构信息

Department of Nutrition, University of California, Davis, CA 95616, USA.

United States Department of Agriculture, Agricultural Research Service-Western Human Nutrition Research Center, Davis, CA 95616, USA.

出版信息

Metabolites. 2025 Jan 3;15(1):14. doi: 10.3390/metabo15010014.

Abstract

Metabolic profiling of human milk (HM) is indispensable for elucidating mother-milk-infant relationships. We evaluated the Biocrates MxP Quant 500 assay for HM-targeted metabolomics (106 small molecules, 524 lipids) and analyzed in a feasibility test HM from apparently healthy Brazilian mothers (A: 2-8, B: 28-50, C: 88-119 days postpartum, n = 25). Of the 630 possible signatures detectable with this assay, 506 were above the limits of detection in an HM-pool (10 µL) used for assay evaluation, 12 of them above the upper limit of quantitation. Analyzing five different HM-pool volumes (2-20 µL) revealed acceptable linearity for 458 metabolites. Intraday accuracy of 80-120% was attained by 469 metabolites after spiking and for 342 after a 1:2 dilution. Analyzing HM from Brazilian mothers revealed significantly lower concentrations in colostrum vs. mature milk for many flow-injection analyses (FIA) and only a few LC-MS metabolites, including triglycerides, sphingomyelins, and phosphatidylcholines. Higher concentrations at the later lactation stages were found predominantly for amino acids and related compounds. The MxP Quant 500 assay is a useful tool for HM metabolic profiling, minimizing analytical bias between matrices, and enhancing our ability to study milk as a biological system.

摘要

人乳(HM)的代谢谱分析对于阐明母婴关系至关重要。我们评估了用于人乳靶向代谢组学的Biocrates MxP Quant 500检测法(106种小分子、524种脂质),并在一项可行性测试中分析了来自表面健康的巴西母亲的人乳(产后2 - 8天的A组、28 - 50天的B组、88 - 119天的C组,n = 25)。在该检测法可检测的630种可能特征中,506种在用于检测评估的人乳混合样本(10 µL)中高于检测限,其中12种高于定量上限。分析五种不同体积(2 - 20 µL)的人乳混合样本发现,458种代谢物具有可接受的线性关系。加标后469种代谢物的日内准确度达到80 - 120%,1:2稀释后342种代谢物达到该准确度。分析巴西母亲的人乳发现,对于许多流动注射分析(FIA)而言,初乳中的浓度显著低于成熟乳,而只有少数液相色谱 - 质谱代谢物(包括甘油三酯、鞘磷脂和磷脂酰胆碱)是这样。在哺乳后期浓度较高的主要是氨基酸及相关化合物。MxP Quant 500检测法是进行人乳代谢谱分析的有用工具,可最大程度减少不同基质间的分析偏差,并增强我们将乳汁作为生物系统进行研究 的能力。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4ca7/11768157/2931bd98d47e/metabolites-15-00014-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验