Souza Alessandra Figueiredo de, Barra Sâmila Gonçalves, Rocha Amanda Leal, Bemquerer Larissa Marques, Oliveira Sicilia Rezende, Carvalho Larissa Nayane, Amaral Tânia Mara Pimenta, Brasileiro Claudia Borges, Costa Fernando Oliveira, Souza Leandro Napier, Camargos Bruno Muzzi, Lima Enaldo Melo de, Ferreira Adaliene Versiani Matos, Heredia Joyce Elisa, Oliveira Marina Chaves de, Macari Soraia, Abreu Lucas Guimarães, Mesquita Ricardo Alves, Silva Tarcília Aparecida
Universidade Federal de Minas Gerais - UFMG, School of Dentistry, Department of Oral Surgery, Pathology and Clinical Dentistry, Belo Horizonte, MG, Brazil.
Universidade Federal de Minas Gerais - UFMG, School of Dentistry, Belo Horizonte, MG, Brazil.
Braz Oral Res. 2025 Feb 21;39:e023. doi: 10.1590/1807-3107bor-2025.vol39.023. eCollection 2025.
The use of aromatase inhibitors (AIs) leads to an imbalance in bone remodeling and can cause osteoporosis. This study aimed to identify clinical, periodontal, nutritional, and biochemical determinants of bone mineral density (BMD) changes in patients using AIs. The sample consisted of 40 women using AIs and 32 controls. BMD was assessed by dual X-ray absorptiometry (DXA). Data on nutritional, anthropometric, oral and periodontal status, and oral health-related quality of life (OHRQoL) were collected. Cytokines and adipokines were quantified in saliva and serum. Thirty-nine of the 72 women had low BMD, with a similar distribution in the control and AIs groups. BMD was lower in older women using AIs (p = 0.009) and in smokers (p = 0.034). Anthropometric assessment demonstrated that women with low BMD who used AIs had lower weight (p = 0.028). Although the frequency of periodontitis was similar in all groups, higher IL-6 (p = 0.004), IL-1β (p = 0.002), and IL-33 (p = 0.006) levels were associated with poor periodontal status. Women who used AIs were 1.18 times more likely to report better OHRQoL than controls. While advanced age, smoking, and lower weight are factors associated with low BMD, the use of antiresorptive agents was a protective factor for maintaining BMD in women using AIs.
芳香化酶抑制剂(AIs)的使用会导致骨重塑失衡,并可能引发骨质疏松症。本研究旨在确定使用AIs的患者骨矿物质密度(BMD)变化的临床、牙周、营养和生化决定因素。样本包括40名使用AIs的女性和32名对照者。通过双能X线吸收法(DXA)评估BMD。收集了有关营养、人体测量、口腔和牙周状况以及口腔健康相关生活质量(OHRQoL)的数据。对唾液和血清中的细胞因子和脂肪因子进行定量分析。72名女性中有39名BMD较低,在对照组和使用AIs的组中分布相似。使用AIs的老年女性(p = 0.009)和吸烟者(p = 0.034)的BMD较低。人体测量评估表明,使用AIs且BMD较低的女性体重较轻(p = 0.028)。尽管所有组中牙周炎的发生率相似,但较高的白细胞介素-6(IL-6,p = 0.004)、白细胞介素-1β(IL-1β,p = 0.002)和白细胞介素-33(IL-33,p = 0.006)水平与牙周状况不佳有关。使用AIs的女性报告OHRQoL较好的可能性是对照组的1.18倍。虽然高龄、吸烟和体重较低是与低BMD相关的因素,但使用抗吸收剂是维持使用AIs女性BMD的保护因素。