Suppr超能文献

在透明矫治器治疗中临床冠长度对上颌中切牙矢状向移动的影响:一项有限元研究

The effects of clinical crown length on the sagittal movement of maxillary central incisor in clear aligner treatment: a finite element exploration.

作者信息

Zhou Chen, Feng Zhicai, Ren Jianhan, Luo Haotian, Ieong Hio Cheng, Li Runze, Qing Yangqiao, Guo Yuqing, Guo Bingyan, Huang Zichun, Cao Yang, Wang Weicai

机构信息

Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, 510055, China.

出版信息

BMC Oral Health. 2025 Mar 8;25(1):357. doi: 10.1186/s12903-025-05726-8.

Abstract

BACKGROUND

The mechanism of force application in clear aligner treatment involves wrapping the clinical crowns, suggesting that the size of the clinical crowns may impact tooth movement. The present finite element study aimed to explore the impact of clinical crown length on the sagittal movement of maxillary central incisor in clear aligner treatment.

METHODS

The standard maxillary dentition model was developed using computer tomography scanning. Finite element models of the maxillary dentition, alveolar bone, periodontal ligament, and aligners were established. Twelve model groups were divided based on different clinical crown lengths and attachments' position to simulated the tipping and translational movements of the right maxillary central incisor. The dimensions of the short and long clinical crowns were determined based on epidemiological evidence, and appropriate models were constructed by shortening or elongating the normal incisors by 20% along the longitudinal axis of the tooth. Horizontal rectangular attachments were constructed at the clinical crown center of the short, normal and long clinical crowns. These attachments were categorized into four types: no attachment, labial attachment, palatal attachment and labio-palatal attachments. The finite element analysis focused on evaluating the contact pressure distribution on the crown, displacements, rotations, and von Mises stress in PDL of the right maxillary central incisors.

RESULTS

In tipping movement, the long clinical crown exhibited the highest crown displacement and rotation, enhancing the efficiency. In translational movement, the long clinical crown had the lowest TL/CD value, losing less torque during the crown displacement. However, the short clinical crown had the lowest M/F value, with a greater tendency to move bodily rather than long ones. The von Mises stress distribution in PDL was similar between the two types of movement, while the maximum von Mises stress increased with increasing clinical crown lengths in tipping movement. Labio-lingual attachment had the optimal effect in tipping and translational movement.

CONCLUSIONS

Clinical crown length has considerable influences on the efficiency, movement behavior, and maximum von Mises stress of the PDL in the sagittal movement of maxillary center incisor in clear aligner treatment. Moreover, attachments also influence the movement efficiency of the incisor.

摘要

背景

在透明矫治器治疗中,施力机制涉及包裹临床牙冠,这表明临床牙冠的大小可能会影响牙齿移动。本有限元研究旨在探讨临床牙冠长度对透明矫治器治疗中上颌中切牙矢状向移动的影响。

方法

使用计算机断层扫描建立标准上颌牙列模型。建立上颌牙列、牙槽骨、牙周膜和矫治器的有限元模型。根据不同的临床牙冠长度和附件位置分为12个模型组,以模拟右上颌中切牙的倾斜和整体移动。基于流行病学证据确定短和长临床牙冠的尺寸,并通过沿牙齿纵轴将正常切牙缩短或延长20%构建合适的模型。在短、正常和长临床牙冠的临床牙冠中心构建水平矩形附件。这些附件分为四种类型:无附件、唇侧附件、腭侧附件和唇腭侧附件。有限元分析重点评估右上颌中切牙牙冠上的接触压力分布、位移、旋转以及牙周膜中的von Mises应力。

结果

在倾斜移动中,长临床牙冠表现出最高的牙冠位移和旋转,提高了效率。在整体移动中,长临床牙冠的TL/CD值最低,在牙冠位移过程中扭矩损失较小。然而,短临床牙冠的M/F值最低,整体移动的倾向大于长临床牙冠。两种移动类型中牙周膜的von Mises应力分布相似,而在倾斜移动中,最大von Mises应力随临床牙冠长度增加而增加。唇舌侧附件在倾斜和整体移动中具有最佳效果。

结论

在透明矫治器治疗中,临床牙冠长度对上颌中切牙矢状向移动的效率、移动行为以及牙周膜的最大von Mises应力有相当大的影响。此外,附件也会影响切牙的移动效率。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d865/11889771/14d9d75b5359/12903_2025_5726_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验