Suppr超能文献

使用未成熟恒牙的三维预制根管模型研究不同黏结系统对纤维桩与生物陶瓷糊剂拔出粘结强度的影响:一项体外研究。

Effects of Different Cementation Systems on Pull-out Bond Strength of Fibre Post to Bioceramic Putty Using a 3D Prefabricated Root Canal Model of Immature Permanent Teeth: An In-Vitro Study.

作者信息

Alsayed Tolibah Yasser, Awad Mohammed Kheir, Najjar Yasser Munther, Abbara Mohammad Tamer, Almonakel Mhd Bashier, Abou Nassar Jihad, Aljabban Osama, Bshara Nada

机构信息

Department of Pediatric Dentistry, Faculty of Dentistry, Damascus University, Damascus, Syria.

Department of Restorative Dentistry, Faculty of Dentistry, Damascus University, Damascus, Syria.

出版信息

Eur Endod J. 2025 Jan;10(1):47-57. doi: 10.14744/eej.2024.30301.

Abstract

OBJECTIVE

The current study aimed to find the best cementation system for cementing the fibre post with BioCeramic putty: total-etch dual-cure hydrophobic resin cement (TC), Self-adhesive dual-cure hydrophilic resin cement (SC), with SC-modified with a bioceramic sealer (SCB), and glass ionomer cement (GIC).

METHODS

An impression was captured from the immature premolar root canal, followed by scanning and the subsequent design of prefabricated root canal models for immature permanent teeth (PRCMs). A total of forty PRCM replicas were precision-printed using advanced 3D printing technology. Subsequently, etch PRCM underwent meticulous filling with BioCeramic putty and a fibre post. After two hours, the fibre posts were removed and treated with hydrofluoric acid for all groups. Subsequently, fibre posts of groups except the GIC group received silane solution application. The PRCMs were categorised into four groups based on the cementation system employed: TC Group (n=10), SC Group (n=10), SCB Group (n=10), and GIC Group (n=10). After 48 h, the specimens underwent pull-out strength testing using a universal testing machine, performed along an axis parallel to the longitudinal axis of the fibre post at a crosshead speed of 1 mm/min. Failure modes were scrutinised using a stereomicroscope. The acquired data were subjected to robust statistical analyses, employing one-way ANOVA and Tukey HSD tests with a significance level set at α=0.05.

RESULTS

The One-way ANOVA test showed a significant difference in the pull-out bond strength of the groups (p<0.001). Accordingly, the Tukey HSD test revealed that the mean bond strength values were significantly higher in the TC group than in other groups. Adhesive failure had a higher frequency in SC and GIC groups, whereas mixed failure had a higher frequency in TC groups and 3.

CONCLUSION

The TC exhibited significantly superior bond strength to the other groups, particularly concerning the fibre post-cementation to BioCeramic putty. (EEJ-2024-06-094).

摘要

目的

本研究旨在找出用于将纤维桩与生物陶瓷糊剂粘结的最佳粘结系统:全酸蚀双固化疏水树脂粘结剂(TC)、自粘结双固化亲水树脂粘结剂(SC)、用生物陶瓷封闭剂改性的SC(SCB)以及玻璃离子水门汀(GIC)。

方法

从未成熟前磨牙根管获取印模,随后进行扫描并设计未成熟恒牙的预制根管模型(PRCMs)。使用先进的3D打印技术精确打印40个PRCM复制品。随后,对蚀刻后的PRCM用生物陶瓷糊剂和纤维桩进行细致充填。两小时后,取出纤维桩,所有组均用氢氟酸处理。随后,除GIC组外的其他组纤维桩均应用硅烷溶液。根据所采用的粘结系统将PRCMs分为四组:TC组(n = 10)、SC组(n = 10)、SCB组(n = 10)和GIC组(n = 10)。48小时后,使用万能试验机对标本进行拔出强度测试,以1mm/min的十字头速度沿与纤维桩纵轴平行的轴进行。使用体视显微镜检查失效模式。所获得的数据进行稳健的统计分析,采用单因素方差分析和Tukey HSD检验,显著性水平设定为α = 0.05。

结果

单因素方差分析表明各组的拔出粘结强度存在显著差异(p < 0.001)。因此,Tukey HSD检验显示TC组的平均粘结强度值显著高于其他组。SC组和GIC组的粘结失败频率较高,而TC组的混合失败频率较高。

结论

TC组的粘结强度明显优于其他组,尤其是在纤维桩与生物陶瓷糊剂的粘结方面。(EEJ - 2024 - 06 - 094)

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/eee7/11971711/03921fdd2e0b/EEJ-10-047-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验