Suppr超能文献

基于聚(5-氨基吲哚)的电化学免疫传感器用于癌症生物标志物五聚体-3的检测。

Electrochemical immunosensor based on poly(5-aminoindole) for cancer biomarker pentraxin-3 detection.

作者信息

Phasuksom Katesara, Thongwattana Natthaporn, Ariyasajjamongkol Nuttha, Parinyanitikul Napa, Sirivat Anuvat

机构信息

Conductive and Electroactive Polymers Research Unit, The Petroleum and Petrochemical College, Chulalongkorn University, Bangkok, Thailand.

Division of Medical Oncology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.

出版信息

Mikrochim Acta. 2025 Apr 25;192(5):321. doi: 10.1007/s00604-025-07174-1.

Abstract

Pentraxin-3 (PTX-3) plays a critical role in regulating inflammation, immune response, angiogenesis, and tissue remodeling. As a serum biomarker, it holds a potential in cancer diagnostics and monitoring. Elevated expression of PTX-3 has been found in various cancers, namely lung, prostate, gastric, breast, and hepatic cancers. Here, a PTX-3 immunosensor was fabricated by utilizing poly(5-aminoindole) (P5AIn) to increase the current response and the electroactive surface area (ESA). (3-Aminopropyl)triethoxysilane (APTES) was used as a linker and as an electron transfer enhancer. The developed PTX-3 immunosensor (BSA/anti-PTX-3/APTES/P5AIn/SPCE) shows excellent performance for PTX-3 detection in a wide concentration range from 0.0001 to 2000 ng/mL with the LOD of 0.012 pg/mL. Furthermore, the sensor possessed good reproducibility (%RSD = 0.78), a long shelf-life of at least 4 weeks (% RSD = 0.89), and high specificity to PTX-3. The fabricated PTX-3 immunosensor was demonstrated in the measurement of PTX-3 concentrations in real blood serums from gastric patients. It has been shown as a potentially promising portable sensor for cancer diagnostics and monitoring for cancer patients in remote areas with a low cost.

摘要

五聚体-3(PTX-3)在调节炎症、免疫反应、血管生成和组织重塑中起关键作用。作为一种血清生物标志物,它在癌症诊断和监测方面具有潜力。已发现PTX-3在各种癌症中表达升高,即肺癌、前列腺癌、胃癌、乳腺癌和肝癌。在此,通过利用聚(5-氨基吲哚)(P5AIn)来增加电流响应和电活性表面积(ESA),制备了一种PTX-3免疫传感器。(3-氨丙基)三乙氧基硅烷(APTES)用作连接剂和电子转移增强剂。所开发的PTX-3免疫传感器(BSA/抗PTX-3/APTES/P5AIn/SPCE)在0.0001至2000 ng/mL的宽浓度范围内对PTX-3检测表现出优异性能,检测限为0.012 pg/mL。此外,该传感器具有良好的重现性(%RSD = 0.78)、至少4周的长保质期(%RSD = 0.89)以及对PTX-3的高特异性。所制备的PTX-3免疫传感器在胃癌患者实际血清中PTX-3浓度的测量中得到了验证。它已被证明是一种潜在有前景的便携式传感器,可用于偏远地区癌症患者的低成本癌症诊断和监测。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验