Suppr超能文献

评估不同敏感性心脏生物标志物在确定亚临床和临床酮病奶牛心肌损伤中的应用

Evaluation of the Use of Different Sensitive Cardiac Biomarkers in Determining Myocardial Damage in Cows With Subclinical and Clinical Ketoses.

作者信息

Uztimür Murat, Ünal Cennet Nur, Sağiroğlu Meltem

机构信息

Department of Internal Medicine, Faculty of Veterinary Medicine, Bingöl University, Bingol, Turkey.

Deparment of Physiology, Faculty of Veterinary Medicine, Fırat University, Elazığ, Turkey.

出版信息

Vet Med Sci. 2025 May;11(3):e70390. doi: 10.1002/vms3.70390.

Abstract

BACKGROUND

It is unclear whether the increase in BHBA concentration damages the myocardium in ketotic cows. Measurement of troponin is the gold standard in myocardial injury.

OBJECTIVE

The objective of this study was to explore the impact of elevated β-hydroxybutyrate (BHBA) concentrations on myocardial damage in cows diagnosed with subclinical ketosis (SCK) and clinical ketosis (CK). Additionally, the study aimed to elucidate the relationship between heart-type fatty acid-binding protein 3 (H-FABP 3) and high-sensitivity cardiac troponin I (hs-cTnI) concentrations, as well as their correlation with various biochemical parameters that assess myocardial and metabolic health.

METHODS

The animal material used in this study consisted of 30 postpartum Holstein cows, aged between 2 and 5 years. The study group comprised 10 cows with SCK, 10 with CK and 10 cows in the control group (CG).

RESULTS

The concentration of hs-cTnI in cows with CK was significantly higher compared to both the CG (p < 0.005) and the SCK group (p < 0.019). Similarly, the H-FABP 3 concentration in the CK and SCK groups was significantly elevated compared to the CG (p < 0.001). The creatinine kinase myocardial band (CK-MB) levels were significantly higher in cows with CK compared to the CG (p < 0.010). Furthermore, the aspartate aminotransferase (AST) levels in the CK group were significantly elevated compared to the CG (p < 0.011). A significant positive correlation was observed between BHBA concentration and the levels of both hs-cTnI and H-FABP 3 in ketotic cows. Additionally, significant correlations were found between various biochemical parameters (alanine aminotransferase [ALT], AST, CK-MB and phosphorus) and the concentrations of H-FABP 3 and hs-cTnI.

CONCLUSIONS

This study showed that high BHBA concentrations in ketosis cows may indirectly cause myocardial damage. However, future studies need to investigate the relationship between oxidative stress and changes in antioxidant concentrations and troponin.

摘要

背景

目前尚不清楚β-羟基丁酸(BHBA)浓度升高是否会损害酮病奶牛的心肌。肌钙蛋白检测是心肌损伤的金标准。

目的

本研究的目的是探讨β-羟基丁酸(BHBA)浓度升高对诊断为亚临床酮病(SCK)和临床酮病(CK)的奶牛心肌损伤的影响。此外,该研究旨在阐明心脏型脂肪酸结合蛋白3(H-FABP 3)与高敏心肌肌钙蛋白I(hs-cTnI)浓度之间的关系,以及它们与评估心肌和代谢健康的各种生化参数的相关性。

方法

本研究使用的动物材料包括30头产后2至5岁的荷斯坦奶牛。研究组包括10头患有亚临床酮病的奶牛、10头患有临床酮病的奶牛和10头作为对照组(CG)的奶牛。

结果

与对照组(p < 0.005)和亚临床酮病组(p < 0.019)相比,临床酮病奶牛的hs-cTnI浓度显著更高。同样,与对照组相比,临床酮病组和亚临床酮病组的H-FABP 3浓度显著升高(p < 0.001)。与对照组相比,临床酮病奶牛的肌酸激酶心肌型同工酶(CK-MB)水平显著更高(p < 0.010)。此外,与对照组相比,临床酮病组的天冬氨酸氨基转移酶(AST)水平显著升高(p < 0.011)。在酮病奶牛中,观察到BHBA浓度与hs-cTnI和H-FABP 3水平之间存在显著正相关。此外,还发现各种生化参数(丙氨酸氨基转移酶[ALT]、AST、CK-MB和磷)与H-FABP 3和hs-cTnI浓度之间存在显著相关性。

结论

本研究表明,酮病奶牛中高浓度的BHBA可能间接导致心肌损伤。然而,未来的研究需要调查氧化应激与抗氧化剂浓度变化和肌钙蛋白之间的关系。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b200/12051843/6f66d59b6b3b/VMS3-11-e70390-g002.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验