Suppr超能文献

现场盐碘检测仪(OSID)试剂盒:一种用于盐碘化监测的替代工具。

On-site salt iodine detector (OSID) kit: An alternative tool for salt iodization monitoring.

作者信息

Jamilan Mohd Azerulazree, Norizan Nurul Aznyda, Zainuddin Ahmad Ali, Muhammad Noor Ul-Aziha, Asari Filza Noor, Abd Rashed Aswir, Md Noh Mohd Fairulnizal

机构信息

Nutrition, Metabolism and Cardiovascular Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health Malaysia, No. 1, Jalan Setia Murni U13/52, Setia Alam, 40170 Shah Alam, Selangor D.E., Malaysia.

Centre for Nutrition Epidemiology Research, Institute for Public Health, National Institutes of Health, Ministry of Health Malaysia, No. 1, Jalan Setia Murni U13/52, Setia Alam, 40170 Shah Alam, Selangor D.E., Malaysia.

出版信息

MethodsX. 2025 Apr 14;14:103314. doi: 10.1016/j.mex.2025.103314. eCollection 2025 Jun.

Abstract

Iodine fortification of cooking salt prevents iodine deficiency, but current monitoring methods are labor-intensive. Here, we validated the On-Site Salt Iodine Detector (OSID) kit as a reliable tool for salt iodine analysis. The OSID kit was optimized for a salt weight (346.1 ± 4.9 mg) and volume of solution D (39.1 ± 1.2 µL), enabling 100 sample analyses. The validation was by its linearity (10.0-50.0 mg/Kg, R = 0.9956) with limit of detection (LOD, 3.6 mg/Kg), method recovery (89.5 %-99.4 %), intra-assay imprecision (coefficient of variation, CV 5.7 %), inter-assay imprecision (CV 7.0 %) and inter-operator imprecision (CV 6.1 %). A 30.0 mg/Kg iodate and sample S4 used as quality control (QC) for ten days monitoring which resulted within the range of mean±2×standard deviation (SD) (27.2 ± 2.4 mg/Kg and 21.6 ± 5.3 mg/Kg, respectively). The OSID kit showed strong agreement in a Blant-Altman plot when compared with UHPLC (60 salt samples) indicating a reliable and cost-effective alternative for salt iodine monitoring.•The optimization of salt weight and volume of solution D allows 100 analyses per kit.•The OSID kit imprecision validation of <10 % demonstrate excellent precision and reliability of the method.•The result comparison between the OSID kit and the UHPLC reference method suggest a strong agreement in a Blant-Altman plot.

摘要

烹饪盐加碘可预防碘缺乏,但目前的监测方法需要大量人力。在此,我们验证了现场盐碘检测仪(OSID)试剂盒作为盐碘分析可靠工具的有效性。OSID试剂盒针对盐重量(346.1±4.9毫克)和溶液D体积(39.1±1.2微升)进行了优化,可进行100次样品分析。验证内容包括线性(10.0 - 50.0毫克/千克,R = 0.9956)、检测限(LOD,3.6毫克/千克)、方法回收率(89.5% - 99.4%)、批内不精密度(变异系数,CV 5.7%)、批间不精密度(CV 7.0%)和不同操作人员间不精密度(CV 6.1%)。使用30.0毫克/千克碘酸盐和样品S4作为质量控制(QC)进行为期十天的监测,结果在平均值±2×标准差(SD)范围内(分别为27.2±2.4毫克/千克和21.6±5.3毫克/千克)。与超高效液相色谱法(UHPLC)(60个盐样品)相比,OSID试剂盒在布兰德 - 奥特曼图中显示出高度一致性,表明其是盐碘监测的可靠且经济高效的替代方法。

•盐重量和溶液D体积的优化使每个试剂盒可进行100次分析。

•OSID试剂盒<10%的不精密度验证表明该方法具有出色的精密度和可靠性。

•OSID试剂盒与UHPLC参考方法的结果比较表明在布兰德 - 奥特曼图中有高度一致性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5d54/12057994/d0018458b087/ga1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验