Suppr超能文献

内部训练暴露:使用心率变异性的个体化方法的开发与结构验证

Internal training exposure: development and construct validation of an individualised method using heart rate variability.

作者信息

Sheoran Samrat, Stavropoulos-Kalinoglou Antonis, Darrall-Jones Josh, Weaving Dan

机构信息

Centre for Human Performance, Carnegie School of Sport, Leeds Beckett University, Cavendish G08, Headingley Campus, Leeds, LS6 3QT, UK.

Applied Sports Science and Exercise Testing Laboratory, The University of Newcastle, Ourimbah, NSW, Australia.

出版信息

Eur J Appl Physiol. 2025 Jun 11. doi: 10.1007/s00421-025-05841-y.

Abstract

PURPOSE

The aim was to develop and validate an individualised internal training exposure method by deriving weighting factors for each heart rate (HR) from detrended fluctuation analysis of heart rate variability (DFA-α1) during a graded exercise test.

METHODS

Thirty-seven participants (17 females; 32.72 ± 9.26 years; maximal oxygen uptake, O = 48.32 ± 7.95 mL kg min) completed a step- and a ramp incremental test to measure blood lactate (BLa), DFA-α1, and cardiorespiratory fitness (CRF) variables, i.e. speed at lactate, ventilatory thresholds (LTs/VTs), and O. Exponential fitting of the fractional elevation of HR (ΔHR) with BLa (individualised training impulse; iTRIMP) or DFA-α1 (αTRIMP) generated individualised coefficients for both methods. The TRIMP weightings were interpolated values of BLa or DFA-α1 derived at each ΔHR through coefficients to represent individualised physiological intensity. Principal component regression evaluated the relationship between combined CRF variables and the TRIMP coefficients or weightings.

RESULTS

Large inter-individual variation was observed at the same physiological thresholds (ΔHR at LT/VT = 0.51-0.83 and LT/VT = 0.63-0.96), underscoring the need for TRIMP methods to weight ΔHR and account for different exposure at similar intensity. CRF had a moderate relationship with coefficients for iTRIMP and αTRIMP methods (R = 0.52-0.67), but a moderate to strong relationship with their weightings at a fixed ΔHR (R = 0.67-0.78).

CONCLUSION

αTRIMP is a valid and practically accessible method for quantifying internal training exposure using ECG-based HR monitors, which individualises physiological intensity through DFA-α1-derived weightings among individuals of varied fitness exercising at same percentages of HR.

摘要

目的

通过在分级运动试验中对心率变异性(DFA-α1)进行去趋势波动分析,得出每个心率(HR)的加权因子,从而开发并验证一种个性化的内部训练暴露方法。

方法

37名参与者(17名女性;年龄32.72±9.26岁;最大摄氧量,O=48.32±7.95 mL·kg-1·min-1)完成了一个阶梯式和一个斜坡递增试验,以测量血乳酸(BLa)、DFA-α1和心肺适能(CRF)变量,即乳酸速度、通气阈值(LTs/VTs)和O。心率分数升高(ΔHR)与BLa(个性化训练冲动;iTRIMP)或DFA-α1(αTRIMP)的指数拟合为两种方法生成了个性化系数。TRIMP加权是通过系数在每个ΔHR处得出的BLa或DFA-α1的插值,以表示个性化的生理强度。主成分回归评估了综合CRF变量与TRIMP系数或加权之间的关系。

结果

在相同的生理阈值下(LT/VT时的ΔHR=0.51-0.83以及LT/VT时的ΔHR=0.63-0.96)观察到个体间存在较大差异,这突出表明需要TRIMP方法对ΔHR进行加权,并考虑相似强度下的不同暴露情况。CRF与iTRIMP和αTRIMP方法的系数呈中等关系(R=0.52-0.67),但在固定的ΔHR下与它们的加权呈中等至强关系(R=0.67-0.78)。

结论

αTRIMP是一种使用基于心电图的心率监测器量化内部训练暴露的有效且实际可行的方法,它通过在不同体能的个体以相同心率百分比进行运动时,基于DFA-α1得出的加权来实现生理强度的个性化。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验