Morris T W, Sahler L G, Harnish P P, Violante M R
Acta Radiol Diagn (Stockh). 1985 Jul-Aug;26(4):471-5. doi: 10.1177/028418518502600419.
The injection of radiocontrast media into coronary arteries will produce a low incidence of ventricular fibrillation. This study establishes the injection duration (or contact time) required to produce fibrillation during right coronary angiography in dogs using a 370 mg I/ml, meglumine/sodium diatrizoate formulation (Renografin 76, Squibb). The mean contact time required to induce fibrillation was 18.8 +/- 5.8 seconds for 66 injections in 47 dogs. Prolonged ischemia of greater than 170 s did not produce either fibrillation or arrhythmias, therefore fibrillation is caused by properties of the media. The contact time was not significantly influenced by test injections and was not significantly different in repeated experiments. The canine contact time model of contrast media induced ventricular fibrillation is reproducible and will facilitate the study of risk factors that increase the possibility of fibrillation.
将放射性造影剂注入冠状动脉会导致室颤发生率较低。本研究确定了在犬类右冠状动脉造影过程中,使用370 mg I/ml的葡甲胺/泛影酸钠制剂(Renografin 76,施贵宝公司)产生室颤所需的注射持续时间(或接触时间)。在47只犬的66次注射中,诱发室颤所需的平均接触时间为18.8±5.8秒。超过170秒的长时间缺血并未产生室颤或心律失常,因此室颤是由造影剂的特性引起的。接触时间不受试验注射的显著影响,在重复实验中也无显著差异。造影剂诱发犬类室颤的接触时间模型具有可重复性,将有助于研究增加室颤可能性的危险因素。