Suppr超能文献

癌症患者的运动测试特征、安全性及质量:一项系统综述

Exercise Testing Characteristics, Safety, and Quality in Patients with Cancer: A Systematic Review.

作者信息

Edvardsen Elisabeth, Nilsen Tormod Skogstad, Novo Robert, Curry Michael, Adams Scott C, Matsoukas Konstantina, Huang Justin, Lee Jasme, Moskowitz Chaya, Jones Lee W, Scott Jessica M

机构信息

Department of Pulmonary Medicine, Oslo University Hospital, Oslo, Norway.

Institute of Physical Performance, The Norwegian School of Sport Sciences, Oslo, Norway.

出版信息

Mayo Clin Proc Innov Qual Outcomes. 2025 Jun 11;9(4):100628. doi: 10.1016/j.mayocpiqo.2025.100628. eCollection 2025 Aug.

Abstract

OBJECTIVE

To evaluate exercise testing (ExT) characteristics, safety, and methodological quality in oncology settings.

PATIENTS AND METHODS

In this systematic review, we searched electronic databases (PubMed, Embase, CINAHL, and Cochrane Library) from inception to March 2024. Studies using ExT to evaluate cardiorespiratory fitness or functional capacity in adults with a history of cancer were included. Summary data including ExT characteristics (eg, modality, cardiorespiratory fitness, and functional capacity results), safety (eg, adverse events [AE]), and methodological quality (eg, guideline adherence) was evaluated.

RESULTS

A total of 642 unique studies with 94,960 patients (58.6±9.9 years; 49% women) were included. Among the 26 ExT modalities used, the maximal cardiopulmonary exercise test (CPET) with measurement of gas exchange (n=284, 40%) and the 6-minute walk test (6MWT) (n=240, 34%) were the most frequently performed. Of the 284 studies that conducted CPET, n=204 (72%) studies reported peak oxygen consumption in mL·kg·min; average peak oxygen consumption was 21.8±5.8 mL·kg·min. Of the 237 studies that conducted 6MWT, 155 (65%) reported distance in meters (m); average distance was 445m±79 m. A total of n=36 (23%) studies reported an average distance above 500 meter. The AEs were monitored in 58 (9.0%) studies wherein a total of 120 non-serious AEs were reported among n=5699 patients (0.02%). Methodological quality and reporting varied considerably.

CONCLUSION

The findings of this systematic review indicate that CPET with gas exchange and field-based tests such as the 6MWT are widely used; however, future research should prioritize improving safety monitoring, appropriate test selection, and methodological consistency to enhance the applicability of ExT in oncology care.

摘要

目的

评估肿瘤学环境中运动测试(ExT)的特征、安全性和方法学质量。

患者与方法

在本系统评价中,我们检索了从数据库建立至2024年3月的电子数据库(PubMed、Embase、CINAHL和Cochrane图书馆)。纳入使用ExT评估有癌症病史成年人的心肺适能或功能能力的研究。评估汇总数据,包括ExT特征(如方式、心肺适能和功能能力结果)、安全性(如不良事件[AE])和方法学质量(如指南依从性)。

结果

共纳入642项独特研究,涉及94,960名患者(58.6±9.9岁;49%为女性)。在使用的26种ExT方式中,测量气体交换的最大心肺运动测试(CPET)(n = 284,40%)和6分钟步行测试(6MWT)(n = 240,34%)是最常进行的。在进行CPET的284项研究中,n = 204(72%)项研究报告了以mL·kg·min为单位的峰值耗氧量;平均峰值耗氧量为21.8±5.8 mL·kg·min。在进行6MWT的237项研究中,155项(65%)报告了以米(m)为单位的距离;平均距离为445 m±79 m。共有n = 36项(23%)研究报告平均距离超过500米。58项(9.0%)研究监测了不良事件,其中在n = 5699名患者中总共报告了120起非严重不良事件(0.02%)。方法学质量和报告差异很大。

结论

本系统评价的结果表明,测量气体交换的CPET和基于实地的测试如6MWT被广泛使用;然而,未来的研究应优先改进安全监测、选择合适的测试以及方法学的一致性,以提高ExT在肿瘤护理中的适用性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7adb/12182365/2a994c71b354/gr1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验