Sović Ivana, Brentin Matija, Vučković Mirela, Lekić Andrica, Starčević-Klasan Gordana, Miletić Bojan, Vlahović Hrvoje
Department of Basic Medical Sciences, Faculty of Health Studies, University of Rijeka, Viktora Cara Emina 5, 51000 Rijeka, Croatia.
Special Hospital for Medical Rehabilitation of Heart, Lung and Rheumatic Diseases-Thalassotherapia Opatija, Ul. Maršala Tita 188, 51410 Opatija, Croatia.
J Funct Morphol Kinesiol. 2025 Jun 27;10(3):245. doi: 10.3390/jfmk10030245.
: Motor irradiation is a concept in which the muscles of the talocrural joint can influence the torque of the quadriceps femoris muscle. The aims of this study are to compare the effects of three different talocrural joint positions on the torque of the quadriceps femoris muscle and to analyze the differences in torque measurements between two dynamometers. : 33 students from the Faculty of Health Studies at the University of Rijeka participated in the study. The torque of the quadriceps femoris muscle was measured using the Cybex CSMi isokinetic dynamometer and the EasyForce hand-held fixed dynamometer. The measurements were performed three times continuously for each talocrural joint position. : When measured with the isokinetic dynamometer ( = 0.210) and the EasyForce dynamometer ( = 0.925), no significant difference was found in the torque of the quadriceps femoris muscle between the three talocrural joint positions. The dynamometers measured the torque consistently and showed a significant, from very good to excellent correlation of the data ( < 0.001), but did not provide identical results due to constant and proportional differences. : There was no significant influence of the three talocrural joint positions on the torque of the quadriceps femoris muscle under isometric contraction conditions without a specific angular velocity. The use of the two dynamometers led to similar but inconsistent results in the measurement of muscle torque. This inconsistency is not only because of the differences between the devices themselves, but also due to fundamental methodological differences in participant stabilization and testing procedures.
踝关节运动辐照是一个概念,即踝关节的肌肉可以影响股四头肌的扭矩。本研究的目的是比较三种不同踝关节位置对股四头肌扭矩的影响,并分析两种测力计之间扭矩测量的差异。里耶卡大学健康研究学院的33名学生参与了该研究。使用Cybex CSMi等速测力计和EasyForce手持式固定测力计测量股四头肌的扭矩。每个踝关节位置连续进行三次测量。使用等速测力计(=0.210)和EasyForce测力计(=0.925)测量时,三个踝关节位置之间股四头肌的扭矩没有显著差异。测力计对扭矩的测量具有一致性,数据显示出显著的、从非常好到优秀的相关性(<0.001),但由于恒定和比例差异,结果并不相同。在没有特定角速度的等长收缩条件下,三个踝关节位置对股四头肌的扭矩没有显著影响。使用这两种测力计在测量肌肉扭矩时得出了相似但不一致的结果。这种不一致不仅是因为设备本身的差异,还由于参与者稳定和测试程序的基本方法差异。