Suppr超能文献

荧光素二月桂酸酯胰腺功能试验的可重复性

Reproducibility of the fluorescein dilaurate pancreatic function test.

作者信息

Keller J, Ornsholt J, Andersen F, Munck V

出版信息

Scand J Clin Lab Invest. 1985 Nov;45(7):585-8. doi: 10.3109/00365518509155264.

Abstract

The indirect pancreatic function test, the fluorescein dilaurate test, was performed twice on nine healthy volunteers. The test is based on the renal excretion of fluorescein liberated from an ingested fluorescein ester by pancreatic enzymes. As a control, fluorescein sodium was ingested under similar conditions. The results of the test are expressed as the ratio of the amount of fluorescein excreted in the test part and the control part, forming the test/control (T/C) ratio. The mean values of excreted fluorescein correlated well with those reported by other authors. The coefficient of variation was 35% in the repeated test and of the same order in the series of individuals. The test cannot be recommended as a quantitative test until further investigation has been performed. Its use as a screening test is found questionable.

摘要

对9名健康志愿者进行了两次间接胰腺功能测试,即荧光素二月桂酸酯测试。该测试基于胰腺酶从摄入的荧光素酯中释放出的荧光素经肾脏排泄的原理。作为对照,在类似条件下摄入荧光素钠。测试结果以测试部分和对照部分排泄的荧光素量之比表示,形成测试/对照(T/C)比值。排泄荧光素的平均值与其他作者报道的结果相关性良好。重复测试中的变异系数为35%,在个体系列中也处于同一水平。在进行进一步研究之前,该测试不能作为定量测试推荐。发现将其用作筛查测试存在疑问。