Transfusion. 1985 Nov-Dec;25(6):540-4. doi: 10.1046/j.1537-2995.1985.25686071426.x.
In November 1984, the Standards Committee of the American Association of Blood Banks changed the requirements for pretransfusion testing by making the performance of an antiglobulin crossmatch optional when the antibody screening test is negative. The crossmatch would be necessary only to confirm ABO compatibility. Many will welcome this change; others will persist in their current methods. This article presents data supporting the use of the manual hexadimethrine bromide (Polybrene) test, a 1-minute room temperature procedure, as a crossmatch technique when the antibody screening test is negative. The manual Polybrene test (MPT) is an effective method for detecting ABO incompatibility. Forty-seven randomly selected serums gave expected results with A1, A2, and B red cells. Only 66 percent of 84 group B sera were serologically incompatible with A2B red cells by MPT, but the same results (69% positive) were observed using a 5-minute low-ionic-strength solution (LISS) room temperature technique. As only 37 percent of these crossmatches were incompatible using a LISS immediate spin (IS) method, the reliability of an IS method is questioned. An MPT crossmatch provides added security in that most unexpected blood group antibodies are demonstrable by this method. Of 106 serums tested which contained antibodies, 83 reacted. We believe that the MPT provides a rapid and sensitive test that, accompanied by a carefully performed antibody screening test, meets the requirements of Standards and will provide for safe red cell transfusion without the need for an antiglobulin crossmatch.
1984年11月,美国血库协会标准委员会更改了输血前检测要求,规定当抗体筛查试验呈阴性时,抗球蛋白交叉配血试验可选择性进行。交叉配血仅用于确认ABO血型相容性。许多人会欢迎这一变化;其他人则会坚持使用当前的方法。本文提供的数据支持在抗体筛查试验呈阴性时,使用手动溴化己二甲铵(聚凝胺)试验(一种1分钟室温操作)作为交叉配血技术。手动聚凝胺试验(MPT)是检测ABO血型不相容性的有效方法。47份随机选择的血清与A1、A2和B型红细胞反应得出预期结果。通过MPT检测,84份B型血清中只有66%在血清学上与A2B型红细胞不相容,但使用5分钟低离子强度溶液(LISS)室温技术观察到相同结果(69%呈阳性)。由于使用LISS立即离心(IS)方法时,这些交叉配血中只有37%不相容,因此IS方法的可靠性受到质疑。MPT交叉配血提供了额外的安全性,因为大多数意外血型抗体可通过该方法检测出来。在检测的106份含有抗体的血清中,83份发生了反应。我们认为,MPT提供了一种快速且灵敏的检测方法,结合精心进行的抗体筛查试验,符合标准要求,无需进行抗球蛋白交叉配血即可实现安全的红细胞输血。