[Advantages and constraints of recent multichannel selective analyzers].

作者信息

Grafmeyer D, Vassault A, Feuillu A, Naudin C

出版信息

Ann Biol Clin (Paris). 1985;43(2):177-82.

PMID:4073610
Abstract

The analyzers have been defined as follows: the analyzers are multiparametric (at least 5 parameters available simultaneously), selective, operating patient by patient, list price on May 1, 1984 below 1,000,000 francs, and distributed in France after January 1, 1981. This definition applies in particular to systems already widely used in French Laboratories, such as the Technicon RA 1000, and the Hitachi Boehringer 705. It also applies to systems distributed more recently, such as the Kone "Progress" and the Coultronics "Dacos". Based on data provided by the manufacturers (technical instructions, operating instructions, evaluation reports, etc) and data provided by a certain number of users, we have tried to appraise the advantages and constraints of these analyzers with respect to the following points: required environment (installation, electrical current, temperature), training of personnel, ease of adaptation, work organization, rhythms, operating cost, ease of use, verification of correct function, format of results, maintenance, etc. Lastly, we discuss the problem of the reliability of the results (precision, accuracy), in particular the problems of referencing in substrate assays, and the problems of accuracy in the measurement of enzymatic activities, considering the current norms of standardization.

摘要

相似文献

1
[Advantages and constraints of recent multichannel selective analyzers].
Ann Biol Clin (Paris). 1985;43(2):177-82.
2
Evaluation of the Olympus AU 400 clinical chemistry analyzer.奥林巴斯AU 400临床化学分析仪评估
Clin Lab. 2000;46(1-2):1-6.
3
Ca2+ measurement with ion selective electrodes. The French coordinated evaluation of seven analyzers, for a better clinical relevance and acceptance.
Ann Biol Clin (Paris). 1988;46(7):419-34.
4
Analytical performance of the random access analyser Hitachi 737. A multicentre evaluation.
J Clin Chem Clin Biochem. 1986 Jun;24(6):409-32.
5
Laboratory evaluation of the Koné "Progress" discrete analyzer.
Clin Chem. 1987 Jan;33(1):123-5.
6
Calibration verification for Olympus and Hitachi automatic biochemistry analyzers using albumin.使用白蛋白对奥林巴斯和日立自动生化分析仪进行校准验证。
Clin Lab. 2012;58(1-2):153-9.
7
Inadequate measurement of urinary chloride.尿氯测量不足。
Ann Clin Lab Sci. 1998 Nov-Dec;28(6):347-53.
8
[Multicenter evaluation on different analyzers of three methods for direct HDL-cholesterol assay].[三种直接高密度脂蛋白胆固醇检测方法在不同分析仪上的多中心评估]
Ann Biol Clin (Paris). 1999 Sep-Oct;57(5):561-72.
9
Ektachem analyzers for the office.
Med Lett Drugs Ther. 1988 Dec 30;30(782):119-20.
10
The serum anion gap. Has the reference interval really fallen?血清阴离子间隙。参考区间真的降低了吗?
Arch Pathol Lab Med. 1997 Jun;121(6):568-72.