Yang Ting, Qu Zheng, Yao Shan, Wu Yingyi, Yin Ting, Song Bin, Ye Zheng
Department of Radiology, West China Hospital, Sichuan University, Chengdu, China.
School of Allied Health Sciences, West China School of Medicine/West China Hospital, Sichuan University, Chengdu, China.
Quant Imaging Med Surg. 2025 Aug 1;15(8):6838-6851. doi: 10.21037/qims-2024-2894. Epub 2025 Jul 30.
Although simultaneous multislice (SMS) acceleration shortens abdominal diffusion-weighted imaging (DWI) scans, its effect on quantitative hepatocellular carcinoma (HCC) measurements is unclear. This study aimed to evaluate SMS acceleration effects on DWI-derived quantitative measurements in HCC and the upper abdominal solid organs.
This prospective cross-sectional study initially enrolled 205 patients with clinically suspected HCC. Free-breathing conventional (CON) and SMS-accelerated monoexponential DWI, diffusion kurtosis imaging (DKI), and intravoxel incoherent motion (IVIM) were performed. Two radiologists independently measured the apparent diffusion coefficient (ADC) for monoexponential DWI, mean kurtosis, and mean diffusivity for DKI, as well as the pure diffusion coefficient and perfusion fraction () for IVIM, in HCC and the upper abdominal solid organs. Paired -tests or Wilcoxon signed-rank tests were used to compare the quantitative diffusion parameters between CON and SMS-accelerated sequences.
A total of 113 patients comprising 129 HCCs were included in the study. The ADC values from SMS-DWI were significantly lower than those from CON-DWI in HCC (P=0.003). Moreover, the values from SMS-IVIM were significantly lower than those from CON-IVIM in HCC (P<0.001), liver parenchyma (P=0.005), right kidney (P=0.002), and left kidney (P=0.005). Other quantitative diffusion parameters did not differ significantly between CON and SMS-accelerated sequences (all P values >0.008).
Compared with CON sequences, SMS acceleration did not affect most quantitative parameters in HCC or the upper abdominal organs. However, the monoexponential DWI-derived ADC value and IVIM-derived value on SMS-accelerated sequences should be interpreted with caution.
尽管同时多切片(SMS)加速可缩短腹部扩散加权成像(DWI)扫描时间,但其对肝细胞癌(HCC)定量测量的影响尚不清楚。本研究旨在评估SMS加速对HCC及上腹部实性器官DWI衍生定量测量的影响。
这项前瞻性横断面研究最初纳入了205例临床疑似HCC的患者。进行了自由呼吸常规(CON)和SMS加速单指数DWI、扩散峰度成像(DKI)和体素内不相干运动(IVIM)检查。两名放射科医生独立测量了HCC及上腹部实性器官中单指数DWI的表观扩散系数(ADC)、DKI的平均峰度和平均扩散率,以及IVIM的纯扩散系数和灌注分数()。采用配对t检验或Wilcoxon符号秩检验比较CON序列和SMS加速序列之间的定量扩散参数。
本研究共纳入113例患者,包含129个HCC。HCC中,SMS-DWI的ADC值显著低于CON-DWI(P = 0.003)。此外,HCC(P < 0.001)、肝实质(P = 0.005)、右肾(P = 0.002)和左肾(P = 0.005)中,SMS-IVIM的 值显著低于CON-IVIM。CON序列和SMS加速序列之间的其他定量扩散参数无显著差异(所有P值>0.008)。
与CON序列相比,SMS加速不影响HCC或上腹部器官的大多数定量参数。然而,对于SMS加速序列上单指数DWI衍生的ADC值和IVIM衍生的 值,应谨慎解读。