Suppr超能文献

[自动凝血分析仪性能评估:伊莱克特拉700]

[Evaluation of the performance of an automatic coagulation tester: the Electra 700].

作者信息

Cambus J P, Biermé R, Martinou J C, Dousset B

出版信息

Nouv Rev Fr Hematol (1978). 1985;27(5):313-20.

PMID:4080541
Abstract

The Electra 700, an automatic coagulation tester recently available in France, was investigated for its performance on routine tests: Quick's test, APTT, thrombin clotting time test, assay of fibrinogen and prothrombin complex factors. Reproducibility was exceptionally good for Quick's test (CV less than 1%), excellent for the other tests (CV less than 3%), acceptability of the various commercial reagents very good, and standard linearity excellent. There was close correlation with manually obtained (electromagnetic B.M.) or semiautomated (KC 10) results (0.9948 to 0.9345). The apparatus is entirely automatic once specimens have been loaded, and it is particularly adapted to dealing with long series of specimens (60 samples). Its original loading system makes it possible to carry out two types of test concurrently, as well as to insert emergency tests. Economically, the cost of disposables and "reagent loss" is satisfactory; however, all tests are carried out relatively slowly, though this is compensated for by the fact that the reactions are completely automatic.

摘要

伊莱克特拉700型全自动凝血分析仪最近在法国上市,对其在常规检测中的性能进行了研究,包括奎克试验、活化部分凝血活酶时间(APTT)、凝血酶凝血时间试验、纤维蛋白原测定及凝血酶原复合物因子检测。奎克试验的重复性极佳(变异系数小于1%),其他检测的重复性良好(变异系数小于3%),各种商用试剂的可接受性非常好,标准线性也很出色。与手动(电磁B.M.)或半自动(KC 10)检测结果具有密切相关性(0.9948至0.9345)。一旦装载样本,该仪器完全自动运行,特别适合处理大量样本(60个样本)。其独特的装载系统能够同时进行两种类型的检测,还可插入急诊检测。在经济性方面,一次性用品成本和“试剂损耗”令人满意;然而,所有检测相对较慢,不过反应完全自动这一事实对此有所弥补。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验