Development and application of a long dynamic range nitrous oxide monitoring system.

作者信息

Ward B G

出版信息

Am Ind Hyg Assoc J. 1985 Dec;46(12):697-703. doi: 10.1080/15298668591395580.

DOI:10.1080/15298668591395580
PMID:4083251
Abstract

The laboratory and field evaluation of a nitrous oxide monitor for an extremely wide range of cumulative exposures are reviewed. The passive sampling behavior and high analyte capacity show it to be useful for short-term and full workweek exposure monitoring. The monitor has application for both area and personnel surveillance. The principal criterion is for an accurate report of exposure time of the monitor. Application of the monitor to real workplace environments--with and without a reference method--demonstrated the ability of workweek monitoring as a valuable and potentially superior way of documenting exposure stress of employees. Environmental factors such as humidity and temperature variation are shown to have acceptably small effects on both short- and long-term exposure data; barometric pressure affects the data in a predictable manner. Paired dosimeters show good agreement in the workplace environment throughout the range of 6-40 cumulative hours of exposure. In both hospital and dental operating suites, work logistics and work group relationships were readily traceable on a week-by-week basis during a continuous weekly monitoring program. Source emissions and appropriate worker and work area exposure relationships were clearly evident, with appropriate reduction of all exposures as a result of an abbreviated work schedule. The ability to effectively track employee and area exposure excursions in an integrated weekly manner leads to a whole series of new applications and concepts of industrial hygiene surveillance. Such approaches could effectively replace the speculative statistical approaches currently in use with actual data on a cost effective basis.

摘要

相似文献

1
Development and application of a long dynamic range nitrous oxide monitoring system.
Am Ind Hyg Assoc J. 1985 Dec;46(12):697-703. doi: 10.1080/15298668591395580.
2
[Evaluation of occupational exposure to inhalation anesthetics. Study Group on Environmental Monitoring, Biological Monitoring and Laboratory Surveillance in Lombardia].[伦巴第大区环境监测、生物监测与实验室监测研究组:吸入性麻醉剂职业暴露评估]
G Ital Med Lav. 1988 Mar;10(2):49-55.
3
Nitrous Oxide Exposure Among Dental Personnel and Comparison of Active and Passive Sampling Techniques.牙科医护人员接触一氧化二氮的情况以及主动和被动采样技术的比较。
Ann Work Expo Health. 2019 Mar 29;63(3):337-348. doi: 10.1093/annweh/wxz003.
4
Optical fiber analyzer for in situ determination of nitrous oxide in workplace environments.
J Environ Monit. 2009 Apr;11(4):852-7. doi: 10.1039/b817639f. Epub 2009 Feb 6.
5
[Occupational exposure to enflurane and laughing gas in operating rooms].[手术室中职业性接触安氟醚和笑气]
Zentralbl Hyg Umweltmed. 1996 Feb;198(3):265-74.
6
[Pollution of the work environment by volatile anesthetics and nitrous oxide].[挥发性麻醉剂和氧化亚氮对工作环境的污染]
Anasthesiol Intensivmed Notfallmed Schmerzther. 1997 Sep;32(9):532-40. doi: 10.1055/s-2007-995107.
7
Assessing workplace chemical exposures: the role of exposure monitoring.评估工作场所的化学暴露:暴露监测的作用。
J Environ Monit. 2004 May;6(5):404-12. doi: 10.1039/b314697a. Epub 2004 Mar 11.
8
Field evaluation of a transportable open-path FTIR spectrometer for real-time air monitoring.
Appl Occup Environ Hyg. 2002 Feb;17(2):131-43. doi: 10.1080/104732202317201375.
9
A field study to assess the long-term sampling feasibility of evacuated canisters and the development of a mathematical model to analyze potential sampling bias.一项实地研究,旨在评估抽空罐的长期采样可行性,并开发一个数学模型以分析潜在的采样偏差。
J Occup Environ Hyg. 2005 Sep;2(9):474-80. doi: 10.1080/15459620500252779.
10
Field comparison between two nitrous oxide (N2O) passive monitors and conventional sampling methods.
Am Ind Hyg Assoc J. 1984 Dec;45(12):812-6. doi: 10.1080/15298668491400692.

引用本文的文献

1
Summary of the scientific literature for pain and anxiety control in dentistry. Journal literature, January-December, 1985.牙科疼痛与焦虑控制的科学文献综述。期刊文献,1985年1月至12月。
Anesth Prog. 1986 Sep-Oct;33(5):268-77.