Suppr超能文献

Robot-assisted total knee arthroplasty demonstrates superior radiological but comparable clinical outcomes compared to conventional techniques: A meta-analysis of prospective studies.

作者信息

Klincke Victor, Huyghe Renee, Vermue Hannes, Martens Manuel, Victor Jan

机构信息

Department of Orthopaedic Surgery and Traumatology, Ghent University, Ghent, Belgium.

出版信息

Knee Surg Sports Traumatol Arthrosc. 2025 Sep 9. doi: 10.1002/ksa.70007.

Abstract

PURPOSE

Robot-assisted total knee arthroplasty (RATKA) aims to improve surgical precision and outcomes. This study compared clinical and radiological outcomes between RATKA and conventional total knee arthroplasty (CTKA).

METHODS

A systematic review was conducted in accordance with PRISMA guidelines, including prospective studies (Level I/II evidence) from MEDLINE, Embase, Web of Science, and the Cochrane Library, up to 20 May 2025. Clinical outcomes included knee function, pain and quality-of-life scores, assessed at a minimum of one year postoperatively. Complications rates were also collected. Radiological outcomes included assessment of coronal and sagittal limb alignment, joint line restoration, and three-dimensional implant positioning. Risk of bias was assessed using validated tools.

RESULTS

Of 11,916 screened citations, 20 studies (11 RCTs, 9 prospective cohort studies) involving 2421 patients (1268 RATKA; 1153 CTKA) were included, with follow-up ranging from 3 months to 2 years and seven different robotic systems evaluated. Meta-analysis showed that RATKA was associated with improved range of motion (mean difference 5.03°; 95%CI [1.78-8.28]; p = 0.004) and WOMAC scores (total, function and pain). No significant differences were found for OKS, KOOS, FJS or EQ-5D. Complication rates were significantly lower in the RATKA group (11.5%) compared to CTKA (16.7%; OR = 0.62; 95%CI [0.45-0.86]; p = 0.004). Radiographically, RATKA significantly improved coronal alignment, joint line restoration, and sagittal tibial positioning, with fewer outliers, compared to conventional TKA. No significant differences were observed in sagittal femoral alignment, posterior tibial slope, or femoral component rotation. Risk of bias was mostly moderate to low, though concerns remained regarding non-blinded assessments, missing data, and potential industry-related conflicts of interest.

CONCLUSIONS

RATKA demonstrated higher precision, reduced radiological outliers and complications compared to CTKA. While clinical scores slightly favoured RATKA, differences were not clinically meaningful. Long-term studies are needed to determine potential benefits in subgroups like severe deformities.

LEVEL OF EVIDENCE

Level II.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验