Suppr超能文献

对不同系统的窄直径种植体进行为期两年的影像学评估。

Radiographic evaluation of narrow-diameter implants from different systems for two years.

作者信息

Fan Xudong, Cheng Xiaoya, Wang Yuanyuan

机构信息

Department of Stomatology, Wuhan No.1 Hospital (Wuhan Hospital of Traditional Chinese and Western Medicine), Wuhan, Hubei, China.

Department of Zhao Jiatiao Outpatient Center, School and Hospital of Stomatology, Wuhan University, Wuhan, Hubei, China.

出版信息

Front Bioeng Biotechnol. 2025 Sep 1;13:1631745. doi: 10.3389/fbioe.2025.1631745. eCollection 2025.

Abstract

BACKGROUND

Narrow-diameter implants (NDIs) offer a viable alternative to bone augmentation in sites with limited alveolar ridge width. This study aimed to retrospectively evaluate the radiographic marginal bone loss (MBL) and survival rate of NDIs from three different systems after 2 years of functional loading.

METHODS

In this retrospective study, a total of 109 NDIs from three brands (30 Straumann, 38 Thommen, and 41 Osstem) in 78 patients were evaluated. Patient records from 2013 to 2023 were screened. Mesial and distal MBL were measured on periapical radiographs at implant loading and at 3, 6, 12, and 24-month follow-ups. MBL was compared based on implant system, gender, and implant location (anterior/posterior, maxilla/mandible).

RESULTS

The overall 2-year implant survival rate was 98.17%. Two implants failed within the first 6 months. The mean MBL at 24 months was 1.67 ± 0.66 mm. Straumann implants (made of TiZr alloy) showed significantly less MBL than Osstem implants (made of Grade IV titanium) at multiple time points (P < 0.05). Female patients exhibited significantly higher mesial MBL than male patients at 6 and 12 months (P < 0.05). Implants in the posterior region showed greater mesial MBL than those in the anterior region at 3 months (P < 0.05).

CONCLUSION

Within the limitations of this study, NDIs demonstrated a high 2-year survival rate, supporting their use in anatomically restricted sites. The implant system, particularly the material and design, significantly influenced MBL. The TiZr alloy implant system was associated with the least bone loss. Patient- and site-specific factors, such as gender and posterior location, were also associated with greater MBL in the early healing phase, highlighting the multifactorial nature of peri-implant bone preservation.

摘要

背景

窄径种植体(NDIs)为牙槽嵴宽度有限的部位提供了一种可行的骨增量替代方案。本研究旨在回顾性评估三种不同系统的窄径种植体在功能负载2年后的影像学边缘骨丢失(MBL)和存留率。

方法

在这项回顾性研究中,对78例患者中来自三个品牌(30枚士卓曼、38枚托曼和41枚奥齿泰)的总共109枚窄径种植体进行了评估。筛选了2013年至2023年的患者记录。在种植体负载时以及3、6、12和24个月随访时,在根尖片上测量近中及远中边缘骨丢失。根据种植体系统、性别和种植体位置(前/后、上颌/下颌)比较边缘骨丢失情况。

结果

2年种植体总体存留率为98.17%。两枚种植体在最初6个月内失败。24个月时的平均边缘骨丢失为1.67±0.66毫米。在多个时间点,士卓曼种植体(由TiZr合金制成)的边缘骨丢失明显少于奥齿泰种植体(由IV级钛制成)(P<0.05)。女性患者在6个月和12个月时的近中边缘骨丢失明显高于男性患者(P<0.05)。在3个月时,后部区域的种植体近中边缘骨丢失大于前部区域的种植体(P<0.05)。

结论

在本研究的局限性内,窄径种植体显示出较高的2年存留率,支持其在解剖结构受限部位的应用。种植体系统,特别是材料和设计,对边缘骨丢失有显著影响。TiZr合金种植体系统的骨丢失最少。患者和部位特异性因素,如性别和后部位置,在早期愈合阶段也与更大的边缘骨丢失相关,突出了种植体周围骨保存的多因素性质。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/aea2/12433985/0b871ae9306f/fbioe-13-1631745-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验