Suppr超能文献

Development and validation of a sustainable spectrofluorimetric method for simultaneous quantification of amlodipine and aspirin using genetic algorithm-enhanced partial least squares regression.

作者信息

Alqahtani Taha, Alqahtani Ali, Almrasy Ahmed A

机构信息

Department of Pharmacology, College of Pharmacy, King Khalid University, Abha, 62529, Saudi Arabia.

Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Al-Azhar University, Cairo, 11751, Egypt.

出版信息

BMC Chem. 2025 Sep 23;19(1):261. doi: 10.1186/s13065-025-01624-w.

Abstract

The widespread clinical utilization of amlodipine-aspirin combinations, despite potential pharmacodynamic interactions and the high prevalence of drug-drug interactions in cardiovascular patients, necessitates robust analytical methods for pharmaceutical quality control and therapeutic drug monitoring. Current analytical approaches face limitations including lengthy analysis times, substantial solvent consumption, and high operational costs. This study presents a novel spectrofluorimetric method coupled with genetic algorithm-enhanced partial least squares (GA-PLS) regression for simultaneous quantification of amlodipine and aspirin in pharmaceutical formulations and biological plasma samples. Synchronous fluorescence spectroscopy at Δλ = 100 nm in 1% sodium dodecyl sulfate-ethanolic medium enhanced spectral characteristics, while chemometric approaches were essential to address remaining spectral overlap for accurate quantification. The GA-PLS approach demonstrated superior performance over conventional partial least squares regression, achieving relative root mean square errors of prediction (RRMSEP) of 0.93 and 1.24 for amlodipine and aspirin respectively, with limits of detection of 22.05 and 15.15 ng/mL. Genetic algorithm optimization reduced spectral variables to approximately 10% of the original dataset while maintaining optimal model performance with only two latent variables. Method validation according to ICH Q2(R2) guidelines demonstrated excellent accuracy (98.62-101.90% recovery) and precision (RSD < 2%) across the analytical range of 200-800 ng/mL. Statistical comparison with established HPLC reference methods showed no significant differences, while application in human plasma achieved recoveries of 95.58-104.51% with coefficient of variation below 5%. Multi-dimensional sustainability assessment using the MA Tool and RGB12 whiteness evaluation achieved an overall score of 91.2%, demonstrating clear superiority over conventional HPLC-UV (83.0%) and LC-MS/MS (69.2%) methods across environmental, analytical, and practical dimensions. The developed method provides a sustainable, cost-effective alternative for routine pharmaceutical analysis, demonstrating enhanced performance through intelligent variable selection and improved operational efficiency.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d7e3/12455781/6f1a2b8ae0d6/13065_2025_1624_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验