Suppr超能文献

Automated strabismus evaluation: a critical review and meta-analysis.

作者信息

Hartness Emma M, Jiang Fangfang, Zamba Gideon K D, Allen Caroline, Bragg Tara L, Nellis Julie, Dumitrescu Alina V, Kardon Randy H

机构信息

Carver College of Medicine, University of Iowa, Iowa City, IA, United States.

Department of Biostatistics, University of Iowa, Iowa City, IA, United States.

出版信息

Front Neurol. 2025 Sep 10;16:1620568. doi: 10.3389/fneur.2025.1620568. eCollection 2025.

Abstract

INTRODUCTION

Adult strabismus has a wide range of etiologies and necessitates clinical evaluation for appropriate treatment. Advancements in eye tracking technology show promise for the development of clinically accurate, automated evaluation and diagnosis of peripheral and central causes of ocular misalignment. However, multiple barriers prevent the incorporation of automated devices into clinical use. This study aimed to perform a quantitative meta-analysis and qualitative assessment of published reports of devices capable of automated strabismus evaluation.

METHODS

A systematic search of the literature was conducted to identify reports of automated strabismus evaluation published between the years 1949-2025. Sixty-nine studies were identified through the literature search, and 17 of these studies qualified for statistical meta-analysis of automated device quality compared to gold standard clinical evaluation. We also analyzed factors affecting clinical use, including device portability, cost, and applicability toward patients with extreme angles of strabismus or anatomic variances, among others.

RESULTS

Meta-analysis demonstrated a pooled estimation of correlation of 0.87 [95% CI: (0.81, 0.91)] between results obtained by devices capable of automated strabismus evaluation in the literature and gold standard clinical evaluation. We identified advantages and limitations of previous models and offered guidelines to facilitate the advancement of device capabilities toward the level of gold standard expert clinical evaluation, and to facilitate the clinical implementation of these devices.

DISCUSSION

While barriers exist between experimental testing and clinical incorporation, automated strabismus technology shows promise for rapid, precise, and accurate evaluation of strabismus and has the potential to expand access to ophthalmic care in cases of low-resource or remote areas that lack local expert clinical personnel.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4b9e/12457155/83a260fc09a8/fneur-16-1620568-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验