Adult strabismus has a wide range of etiologies and necessitates clinical evaluation for appropriate treatment. Advancements in eye tracking technology show promise for the development of clinically accurate, automated evaluation and diagnosis of peripheral and central causes of ocular misalignment. However, multiple barriers prevent the incorporation of automated devices into clinical use. This study aimed to perform a quantitative meta-analysis and qualitative assessment of published reports of devices capable of automated strabismus evaluation.
A systematic search of the literature was conducted to identify reports of automated strabismus evaluation published between the years 1949-2025. Sixty-nine studies were identified through the literature search, and 17 of these studies qualified for statistical meta-analysis of automated device quality compared to gold standard clinical evaluation. We also analyzed factors affecting clinical use, including device portability, cost, and applicability toward patients with extreme angles of strabismus or anatomic variances, among others.
Meta-analysis demonstrated a pooled estimation of correlation of 0.87 [95% CI: (0.81, 0.91)] between results obtained by devices capable of automated strabismus evaluation in the literature and gold standard clinical evaluation. We identified advantages and limitations of previous models and offered guidelines to facilitate the advancement of device capabilities toward the level of gold standard expert clinical evaluation, and to facilitate the clinical implementation of these devices.
While barriers exist between experimental testing and clinical incorporation, automated strabismus technology shows promise for rapid, precise, and accurate evaluation of strabismus and has the potential to expand access to ophthalmic care in cases of low-resource or remote areas that lack local expert clinical personnel.
成人斜视病因广泛,需要进行临床评估以确定合适的治疗方法。眼动追踪技术的进步为开发临床上准确、自动化的眼部斜视评估及诊断外周和中枢病因带来了希望。然而,多种障碍阻碍了自动化设备在临床中的应用。本研究旨在对已发表的能够进行自动化斜视评估的设备报告进行定量荟萃分析和定性评估。
对文献进行系统检索,以确定1949年至2025年间发表的关于自动化斜视评估的报告。通过文献检索确定了69项研究,其中17项研究符合与金标准临床评估相比的自动化设备质量统计荟萃分析的条件。我们还分析了影响临床应用的因素,包括设备便携性、成本以及对斜视角度极大或存在解剖变异患者的适用性等。
荟萃分析表明,文献中能够进行自动化斜视评估的设备所获得的结果与金标准临床评估之间的合并相关性估计为0.87 [95%置信区间:(0.81, 0.91)]。我们确定了先前模型的优点和局限性,并提供了指导方针,以促进设备能力朝着金标准专家临床评估水平发展,并促进这些设备的临床应用。
虽然在实验测试和临床应用之间存在障碍,但自动化斜视技术在快速、精确和准确评估斜视方面显示出前景,并且有潜力在缺乏当地专家临床人员的资源匮乏或偏远地区扩大眼科护理的可及性。