Mayner R E, Blackburn R J, Barry D W
Dev Biol Stand. 1977;39:169-78.
A technique for the quantitation of hemagglutinin (HA) in influenza vaccines by immunoelectrophoresis (IEP) is described. This method gives accurate, and reproducible results and requires approximately 9 h to complete. The HA content of four manufacturers' vaccines correlated with the chick cell agglutination (CCA) values for each manufacturers' vaccine. However, when comparisons were made between vaccines produced by different manufacturers, up to a four-fold difference in HA content was observed. Comparison with single radial immunodiffusion (SRID) gave comparable results for vaccines produced by three of four manufacturers; the fourth manufacturers' vaccine gave 1.6-fold higher results by SRID. Human seroconversion rates in seronegative individuals correlated better with IEP determined HA content than the current assay of vaccine potency using CCA.
本文描述了一种通过免疫电泳(IEP)定量流感疫苗中血凝素(HA)的技术。该方法结果准确、可重复,完成检测大约需要9小时。四个制造商疫苗的HA含量与各制造商疫苗的鸡胚细胞凝集(CCA)值相关。然而,当比较不同制造商生产的疫苗时,观察到HA含量存在高达四倍的差异。与单向放射免疫扩散法(SRID)比较,四个制造商中有三个制造商生产的疫苗结果相当;第四个制造商的疫苗通过SRID检测得到的结果高出1.6倍。血清阴性个体的人体血清转化率与IEP测定的HA含量的相关性比目前使用CCA检测疫苗效力的方法更好。