Suppr超能文献

生物人工瓣膜患者的二维超声心动图评估

Two dimensional echocardiographic assessment of patients with bioprosthetic valves.

作者信息

Schapira J N, Martin R P, Fowles R E, Rakowski H, Stinson E B, French J W, Shumway N E, Popp R L

出版信息

Am J Cardiol. 1979 Mar;43(3):510-9. doi: 10.1016/0002-9149(79)90007-9.

Abstract

The clinical utility of two dimensional echocardiography in assessing bioprosthetic and left ventricular function was studied in 40 consecutive patients 1 week to 60 months after valve replacement surgery. These patients were referred to obtain normal baseline studies as well as to evaluate complications:suspected endocarditis, embolic phenomena and congestive heart failure of unknown cause. Independent M mode echocardiograms were also obtained in each patient. Confirmation of ultrasonic studies was by cardiac catheterization with angiography, surgery and pathologic study in 10 patients; cardiac catheterization with angiography alone in 7 patients; surgery and pathologic study in 3 patients; autopsy in 3 patients; blood cultures to confirm or exclude endocarditis in 10 patients; and confirmation on clinical grounds in 7 patients. Technically adequate two dimensional studies were recorded in 39 of 40 subjects. Two dimensional echocardiography accurately assessed 15 of 16 patients with an abnormal bioprosthetic valve and a normal left ventricle (1 of 16 patients had a false positive two dimensional echocardiogram); 8 of 8 patients suspected to have prosthetic valve or left ventricular dysfunction but who were normal; 7 of 7 patients with a normal prosthesis and an abnormal left ventricle; the one patient with an abnormal valve and left ventricle; and 7 of 7 clinically normal patients who were referred for baseline studies. In summary, the two-dimensional echocardiogram demonstrated a 97 percent diagnostic accuracy rate which was significantly greater than the 67 percent (P less than 0.001) for M mode echocardiography in the same group of patients. It is concluded that two dimensional echocardiography has excellent diagnostic accuracy in assessing bioprosthetic and left ventricular function and is superior to M mode echocardiography in evaluating patients after such valve replacement.

摘要

在40例瓣膜置换手术后1周龄至60个月龄的连续患者中,研究了二维超声心动图在评估生物瓣膜和左心室功能方面的临床应用价值。这些患者被转诊以获取正常的基线研究结果,并评估并发症:疑似心内膜炎、栓塞现象和不明原因的充血性心力衰竭。同时为每位患者进行独立的M型超声心动图检查。10例患者通过心脏导管造影、手术及病理研究来证实超声检查结果;7例患者仅通过心脏导管造影来证实;3例患者通过手术及病理研究来证实;3例患者通过尸检来证实;10例患者通过血培养来证实或排除心内膜炎;7例患者通过临床依据来证实。40例受试者中有39例记录到技术上足够的二维研究结果。二维超声心动图准确评估了16例生物瓣膜异常但左心室正常的患者中的15例(16例患者中有1例二维超声心动图出现假阳性);8例疑似人工瓣膜或左心室功能障碍但实际正常的患者中的8例;7例人工瓣膜正常但左心室异常的患者中的7例;1例瓣膜和左心室均异常的患者;以及7例因基线研究而转诊的临床正常患者中的7例。总之,二维超声心动图的诊断准确率为97%,显著高于同一组患者中M型超声心动图的67%(P<0.001)。得出结论,二维超声心动图在评估生物瓣膜和左心室功能方面具有出色的诊断准确性,并且在评估此类瓣膜置换术后的患者时优于M型超声心动图。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验