Vilim A B, MacIntosh A I
J Assoc Off Anal Chem. 1979 Jan;62(1):19-22.
A rapid high pressure liquid chromatographic (HPLC) screening method for the quantitative determination of nitrofurazone in milk has been developed. The drug is extracted with ethyl acetate from a 2.0 ml milk serum sample, the organic layer is evaporated to dryness, and the residue is dissolved in the mobile phase and injected into the liquid chromatogarph. A reverse phase muBondapak C18 column is used with monitoring at 365 nm. The detection limit is 5 ppb and recoveries are 57--67%. Mass spectroscopic confirmation of the HPLC nitrofuran peak is described.
已开发出一种用于定量测定牛奶中呋喃西林的快速高压液相色谱(HPLC)筛选方法。从2.0毫升牛奶血清样品中用乙酸乙酯萃取该药物,将有机层蒸发至干,残渣溶解于流动相中并注入液相色谱仪。使用反相μBondapak C18柱,在365纳米处进行监测。检测限为5 ppb,回收率为57%至67%。描述了对HPLC呋喃西林峰的质谱确认。