Tresguerres J A, Oriol Bosch A
Reproduccion. 1974 Jul-Sep;1(3):289-97.
A double antibody radioimmunoassay in estudied for the determination of PGF2alpha. Its sensitivity allows to detect 0.4 ng. The reproductibility in this assays is of 7.8 % while between assays is of 10.7 %. No detectable levels (less than 0.8 ng/ml) could be found on blood obtained from the right heart chambers during the menstrual cycle, but they were measured in peripheral blood during normal deliveries. Changes on PGF2alpha concentrations occur in the endometrium along the menstrual cycle. Tis is a relatively simple method useful either for farmocodinamical studies when administering PGF2alpha or for physiological work with tissure showing relatively high concentrations of this compound.
一种用于测定前列腺素F2α的双抗体放射免疫分析法已被研究。其灵敏度可检测到0.4纳克。该分析方法的重复性为7.8%,不同分析之间的重复性为10.7%。在月经周期中从右心腔采集的血液中未检测到(低于0.8纳克/毫升),但在正常分娩时在外周血中检测到了。前列腺素F2α的浓度在子宫内膜中随月经周期发生变化。这是一种相对简单的方法,在给予前列腺素F2α时可用于药效学研究,也可用于对该化合物浓度相对较高的组织进行生理学研究。