Beachey E H, Ofek I, Cunningham M, Bisno A
Appl Microbiol. 1974 Jan;27(1):1-4. doi: 10.1128/am.27.1.1-4.1974.
Variables involved in micro complement fixation (CF) tests for type-specific (TSM) and non-type-specific (NTSM) antibodies against preparations of streptococcal M protein were studied. Sera of rabbits immunized with purified M protein which contained high titers of anti-TSM and low titers of anti-NTSM antibodies reacted type specifically in the CF tests when relatively low concentrations of M protein were employed. In contrast to these artificially induced TSM antibody responses, the sera of rheumatic fever patients demonstrated elevated CF antibody titers (1:80 to 1:320) in the presence of both high and low concentrations of M antigen. The CF test cannot distinguish TSM and NTSM antibodies when the latter predominate. The CF test can be employed with confidence for the detection of NTSM antibodies, provided that the test sera are known to lack type-specific antibodies against the M protein used in the test.
对针对链球菌M蛋白制剂的型特异性(TSM)和非型特异性(NTSM)抗体进行微量补体结合(CF)试验所涉及的变量进行了研究。用纯化M蛋白免疫的兔血清,其中含有高滴度的抗TSM抗体和低滴度的抗NTSM抗体,当使用相对低浓度的M蛋白时,在CF试验中呈现型特异性反应。与这些人工诱导的TSM抗体反应不同,风湿热患者的血清在高浓度和低浓度M抗原存在下均显示出升高的CF抗体滴度(1:80至1:320)。当NTSM抗体占主导时,CF试验无法区分TSM和NTSM抗体。如果已知试验血清缺乏针对试验中所用M蛋白的型特异性抗体,则CF试验可用于可靠地检测NTSM抗体。