Martin L E, Oxford J, Tanner R J, Hetheridge M J
Biomed Mass Spectrom. 1979 Oct;6(10):460-1. doi: 10.1002/bms.1200061011.
A method is described for the quantitative determination of terbutaline in 2 ml human plasma. The drug is extracted from plasma as the terbutaline tetraphenylboron ion pair and determined by gas chromatography mass spectrometry of its t-butyldimethylsily ether. Salbutamol is used as internal standard. Quantification is achieved by selected ion monitoring of the ion m/z 482 derived from t-butyldimethylsilyl terbutaline and m/z 495 from t-butyldimethylsilyl salbutamol. The detection limit was estimated to be 250 pg terbutaline ml-1 plasma. The coefficient of variation at the level of 1 ng terbutaline ml-1 was 4.1% (n = 5).