Suppr超能文献

Measurement of plasma digoxin concentration by radioimmunoassay.

作者信息

Evered D C, Chapman C, Hayter C J

出版信息

Br Med J. 1970 Aug 22;3(5720):427-8. doi: 10.1136/bmj.3.5720.427.

Abstract

A rapid, sensitive, and precise method for measuring the plasma digoxin concentration has been developed with the radioimmunoassay technique. Seventy patients receiving digoxin were shown to have plasma digoxin concentrations between 0.4 and 5 ng./ml. Preliminary studies show that though there is a positive correlation between total daily dose and the plasma digoxin concentration, the relationship is not close, and a relatively wide range of plasma digoxin concentrations appear to be consistent with effective digitalization.

摘要

相似文献

1
Measurement of plasma digoxin concentration by radioimmunoassay.
Br Med J. 1970 Aug 22;3(5720):427-8. doi: 10.1136/bmj.3.5720.427.
2
Serum digoxin by radioimmunoassay.
Can Med Assoc J. 1971 Jul 24;105(2):170-3.
4
[Plasma-digoxin concentration in patients at time of hospital admission (author's transl)].
Dtsch Med Wochenschr. 1977 Jul 22;102(29):1056-60. doi: 10.1055/s-0028-1105463.
5
Determination of therapeutic and toxic serum digoxin concentrations by radioimmunoassay.
N Engl J Med. 1969 Nov 27;281(22):1212-6. doi: 10.1056/NEJM196911272812203.
7
Plasma digoxin concentrations in patients with atrial fibrillation.
Br Med J. 1970 Aug 22;3(5720):429-32. doi: 10.1136/bmj.3.5720.429.
8
[Simplified rapid determination of plasma digoxin. Methods and clinical evaluation].
Klin Wochenschr. 1975 Mar 1;53(5):215-9. doi: 10.1007/BF01468810.
9
Digoxin measurements in general practice.
Br J Clin Pharmacol. 1977 Jun;4(3):321-6. doi: 10.1111/j.1365-2125.1977.tb00720.x.

引用本文的文献

1
Plasma digoxin concentrations and digoxin toxicity in hospital patients.
Br Heart J. 1971 Jul;33(4):540-5. doi: 10.1136/hrt.33.4.540.
2
Clinical use of a bio-assay of serum digitoxin activity.
Eur J Clin Pharmacol. 1971 Sep;3(4):236-42. doi: 10.1007/BF00565013.
3
Serum digoxin by radioimmunoassay.
Can Med Assoc J. 1971 Jul 24;105(2):170-3.
4
[Determination of serum-digoxin concentrations by radioimmunoassay].
Klin Wochenschr. 1971 Sep 15;49(18):1031-2. doi: 10.1007/BF01487735.
5
Effect of prolonged ouabain treatment of Na, K, Cl and Ca concentration and fluxes in cultured human cells.
J Physiol. 1972 Sep;225(3):599-617. doi: 10.1113/jphysiol.1972.sp009959.
7
An anaesthetic application of serum digoxin radioimmunoassay.
Can Anaesth Soc J. 1972 Jan;19(1):20-34. doi: 10.1007/BF03006904.
9
Plasma digoxin concentrations in patients on admission to hospital.
Br Heart J. 1974 Jul;36(7):707-12. doi: 10.1136/hrt.36.7.707.
10
A rapid, simple assay for digoxin.
J Clin Pathol. 1974 Jun;27(6):490-4. doi: 10.1136/jcp.27.6.490.

本文引用的文献

1
A METHOD FOR MEASURING PLASMA LEVELS OF DIGITALIS GLYCOSIDES.
Circulation. 1965 Feb;31:228-33. doi: 10.1161/01.cir.31.2.228.
2
The distribution and concentration of tritiated digoxin in human tissues.
Ann Intern Med. 1967 Jan;66(1):116-24. doi: 10.7326/0003-4819-66-1-116.
4
Administration of tritiated digoxin with and without a loading dose. A metabolic study.
Circulation. 1966 Nov;34(5):865-74. doi: 10.1161/01.cir.34.5.865.
6
A simple liquid scintillator solution for assay of tritium in plasma or serum.
Int J Appl Radiat Isot. 1969 Aug;20(8):608-11. doi: 10.1016/0020-708x(69)90087-8.
7
Everest MS: Measurement of digoxin in plasma and its use in diagnosis of digoxin intoxication.
Br Med J. 1969 Feb 1;1(5639):286-9. doi: 10.1136/bmj.1.5639.286.
8
The measurement of digitoxin in human serum by radioimmunoassay.
J Clin Invest. 1968 May;47(5):1035-42. doi: 10.1172/JCI105793.
9
Determination of therapeutic and toxic serum digoxin concentrations by radioimmunoassay.
N Engl J Med. 1969 Nov 27;281(22):1212-6. doi: 10.1056/NEJM196911272812203.
10
Plasma and myocardial digoxin concentrations in patients on oral therapy.
Br Heart J. 1969 Sep;31(5):636-40. doi: 10.1136/hrt.31.5.636.

文献AI研究员