A radioimmunoassay for quantitation of beta2-microglobulin in serum and urine is described. Polyethylene glycol 6000 was used to precipitate the antigen-antibody complex. The assay can be performed within 5 hr. In healthy human subjects (mean age, 30.6 years and 42.0 years for serum and urine determinations, respectively) the mean concentration of beta2-microglobulin in serum was 125 nmol/l (range, 49-190 nmol/l). In men the mean 24-hr urinary excretion was 12.9 nmol (range, 8.6-19.2 nmol), and in women it was 5.5 nmol (range, 2.9-8.7 nmol). The assay range was 0.23-19.40 nmol/l, and the detection limit was 0.042 nmol/l, using a prolonged incubation time. The coefficient of variation based on 20 determinations in serum dilutions with a concentration of beta2-microglobulin of 8.14 and 1.92 nmol/l was 8.1 per cent and 9.0 per cent, respectively.

摘要

本文描述了一种用于定量血清和尿液中β2-微球蛋白的放射免疫分析方法。使用聚乙二醇6000沉淀抗原-抗体复合物。该分析可在5小时内完成。在健康人体受试者中(血清和尿液检测的平均年龄分别为30.6岁和42.0岁),血清中β2-微球蛋白的平均浓度为125 nmol/l(范围为49 - 190 nmol/l)。男性24小时尿排泄量平均为12.9 nmol(范围为8.6 - 19.2 nmol),女性为5.5 nmol(范围为2.9 - 8.7 nmol)。使用延长孵育时间时,分析范围为0.23 - 19.40 nmol/l,检测限为0.042 nmol/l。基于对浓度为8.14和1.92 nmol/l的血清稀释液进行20次测定,变异系数分别为8.1%和9.0%。