Suppr超能文献

用于定量酶联免疫吸附测定及其他在微孔板上进行的比色测定的探针比色计。

Probe colorimeter for quantitating enzyme-linked immunosorbent assays and other colorimetric assays performed with microplates.

作者信息

Ackerman S B, Kelley E A

出版信息

J Clin Microbiol. 1983 Mar;17(3):410-3. doi: 10.1128/jcm.17.3.410-413.1983.

Abstract

The performance of a fiberoptic probe colorimeter (model PC800; Brinkmann Instruments, Inc., Westbury, N.Y.) for quantitating enzymatic or colorimetric assays in 96-well microtiter plates was compared with the performances of a spectrophotometer (model 240; Gilford Instrument Laboratories, Inc., Oberlin, Ohio) and a commercially available enzyme immunoassay reader (model MR590; Dynatech Laboratories, Inc., Alexandria, Va.). Alkaline phosphatase-p-nitrophenyl phosphate in 3 M NaOH was used as the chromophore source. Six types of plates were evaluated for use with the probe colorimeter; they generated reproducibility values (100% coefficient of variation) ranging from 91 to 98% when one individual made 24 independent measurements on the same dilution of chromophore on each plate. Eleven individuals each performed 24 measurements with the colorimeter on either a visually light (absorbance of 0.10 at 420 nm) or a dark (absorbance of 0.80 at 420 nm) dilution of chromophore; reproducibilities averaged 87% for the light dilution and 97% for the dark dilution. When one individual measured the same chromophore sample at least 20 times in the colorimeter, in the spectrophotometer or in the enzyme immunoassay reader, reproducibility for each instrument was greater than 99%. Measurements of a dilution series of chromophore in a fixed volume indicated that the optical responses of each instrument were linear in a range of 0.05 to 1.10 absorbance units.

摘要

将用于在96孔微量滴定板中定量酶促或比色测定的光纤探头比色计(型号PC800;Brinkmann仪器公司,纽约州韦斯特伯里)的性能,与分光光度计(型号240;吉尔福德仪器实验室公司,俄亥俄州奥伯林)和市售酶免疫测定读数仪(型号MR590;Dynatech实验室公司,弗吉尼亚州亚历山德里亚)的性能进行了比较。以3M NaOH中的碱性磷酸酶-对硝基苯磷酸作为发色团来源。评估了六种类型的板与探头比色计的兼容性;当一个人在每块板上对相同稀释度的发色团进行24次独立测量时,它们产生的重现性值(变异系数100%)在91%至98%之间。11个人分别使用比色计对发色团的浅(420nm处吸光度为0.10)或深(420nm处吸光度为0.80)稀释液进行了24次测量;浅稀释液的重现性平均为87%,深稀释液的重现性平均为97%。当一个人在比色计、分光光度计或酶免疫测定读数仪中对同一发色团样品进行至少20次测量时,每种仪器的重现性均大于99%。对固定体积的发色团稀释系列进行测量表明,每种仪器的光学响应在0.05至1.10吸光度单位范围内呈线性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/096d/272656/d8820ef53a1c/jcm00140-0039-a.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验