Abstract

We have developed a semi-automated method for measuring five kinds of antiepileptic drugs in serum by successfully adapting commercial competitive-binding enzyme immunoassay kits (MARKIT; Dainippon) for use with a continuous-flow analyzer (Technicon AutoAnalyzer II equipped with a dialyzer). The free enzyme-labeled drug is automatically separated by a microfilter from the competitive immunoreaction mixture between labeled and unlabeled drug for anti-drug immunoglobulin coupled to bacterial cell walls. The concentrations of the antiepileptic drugs in serum samples can be determined by automated measurement of enzyme activity of the enzyme-labeled drugs. Results of the semi-automated method correlated well with those obtained by manual enzyme immunoassay, gas-liquid chromatography, and "high-pressure" liquid chromatography. The correlation coefficients were all greater than 0.95, showing the practicality of this method for therapeutic monitoring of antiepileptic drugs.

摘要

我们成功地将市售竞争性结合酶免疫分析试剂盒(MARKIT;大日本制药)与连续流动分析仪(配备透析器的Technicon AutoAnalyzer II)适配,开发出一种用于测定血清中五种抗癫痫药物的半自动方法。游离的酶标记药物通过微滤器自动从标记药物与未标记药物之间针对与细菌细胞壁偶联的抗药物免疫球蛋白的竞争性免疫反应混合物中分离出来。血清样品中抗癫痫药物的浓度可通过自动测量酶标记药物的酶活性来确定。半自动方法的结果与手动酶免疫分析、气液色谱法和“高压”液相色谱法所得结果相关性良好。相关系数均大于0.95,表明该方法在抗癫痫药物治疗监测中的实用性。