Katz J M, Katz S E
J Assoc Off Anal Chem. 1984 May-Jun;67(3):576-9.
A rapid assay for tetracyclines in premixes and mixed feeds is described, which uses the extraction and dilution systems of AOAC methods, and a strain of Bacillus stearothermophilus ATCC 12980 selected to grow at 40 degrees C. The incubation period is 4.5 h. The rapid assay yields results similar to those obtained using the AOAC methods. For a 50 g chlortetracycline (CTC)/lb commercial premix, the rapid procedure averaged 109.2% of label vs 104.4% obtained using the AOAC method; for a 20 g CTC/lb premix, the rapid procedure averaged 89.2% vs 89.3% obtained with the AOAC method. In 2 commercial premixes containing 50 g oxytetracycline/lb, the rapid assay averaged 127.1 and 110.5% vs 134.7 and 113.5% obtained using the AOAC method. In feed extracts supplemented with CTC equivalent to 25-200 g/ton, rapid assay recoveries averaged 101.9%; recoveries using the AOAC method averaged 110.6%. For feed extracts supplemented with oxytetracycline at the same levels, recoveries by the rapid assay averaged 95.4%, and by the AOAC method, 106.0%.
本文描述了一种用于预混料和配合饲料中四环素的快速检测方法,该方法采用了美国官方分析化学师协会(AOAC)方法的提取和稀释系统,并选用嗜热脂肪芽孢杆菌ATCC 12980在40℃下生长。培养期为4.5小时。该快速检测方法得到的结果与使用AOAC方法得到的结果相似。对于每磅含有50克金霉素(CTC)的商业预混料,快速检测方法的平均结果为标签含量的109.2%,而使用AOAC方法得到的结果为104.4%;对于每磅含有20克CTC的预混料,快速检测方法的平均结果为89.2%,而使用AOAC方法得到的结果为89.3%。在两种每磅含有50克土霉素的商业预混料中,快速检测方法的平均结果分别为127.1%和110.5%,而使用AOAC方法得到的结果分别为134.7%和113.5%。在添加了相当于每吨25 - 200克CTC的饲料提取物中,快速检测方法的回收率平均为101.9%;使用AOAC方法的回收率平均为110.6%。对于添加了相同水平土霉素的饲料提取物,快速检测方法的回收率平均为95.4%,而使用AOAC方法的回收率为106.0%。