In patients undergoing long-term thyroid hormone therapy with constant doses the results of FT4 concentrations measured by radioimmunoassay (FT4-AMERLEX) were compared with calculated FT4 values and related to total thyroxine, serum TBG levels, respectively T4/TBG, to control the validity of radioimmunologic FT4 measurements for clinical routine diagnostic purposes. Based on mathematical analyses on the interdependence of these values the following principles were confirmed: free thyroxine measurements are dependent on total thyroxine with a power of x to the exponent and on T4/TBG-ratio with an exponential function. The percentage of free thyroxine (FT4/TT4 ratio) is inversely and exponentially related to serum TBG concentrations. Indeed, the RIA-FT4 results are largely independent of the concentration of binding globulin within certain limits. In thyroid patients without extrathyroid disorders no grossly false hypo- or hyperthyroid FT4 values are to be expected by deviating thyroxine globulin concentrations.

摘要

在接受恒定剂量长期甲状腺激素治疗的患者中,将放射免疫分析法(FT4-AMERLEX)测定的FT4浓度结果与计算得到的FT4值进行比较,并分别与总甲状腺素、血清TBG水平(即T4/TBG)相关联,以控制放射免疫法测定FT4用于临床常规诊断目的的有效性。基于对这些值相互依存关系的数学分析,证实了以下原则:游离甲状腺素的测量取决于总甲状腺素的x次幂以及T4/TBG比值的指数函数。游离甲状腺素百分比(FT4/TT4比值)与血清TBG浓度呈反比且指数相关。实际上,在一定限度内,放射免疫分析法测定的FT4结果很大程度上与结合球蛋白的浓度无关。在无甲状腺外疾病的甲状腺患者中,甲状腺球蛋白浓度的偏差不会导致FT4值出现严重的假性甲状腺功能减退或亢进。