Lackner K, Brecht G, Janson R, Scherholz K, Lützeler A, Thurn P
Rofo. 1980 Jan;132(1):21-30. doi: 10.1055/s-2008-1056518.
Staging was undertaken in 118 patients with primary lymph node neoplasms; the sensitivity of computer tomography in the paraaortic region was 80%, that of lymphography 89%. Specificity of computer tomography was 93%, of lymphography 95%. In the iliac region, sensitivity was 81% (CT) and 90% (lymphography), and specificity was 90% (CT) and 97% (Lymphography). The value of computer tomography should, however, be stressed, since it can demonstrate lymph nodes not shown by lymphography, including those in the mediastinum, as well as lesions in the spleen, liver and lungs.
对118例原发性淋巴结肿瘤患者进行了分期检查;计算机断层扫描在腹主动脉旁区域的敏感性为80%,淋巴造影为89%。计算机断层扫描的特异性为93%,淋巴造影为95%。在髂骨区域,敏感性分别为81%(计算机断层扫描)和90%(淋巴造影),特异性分别为90%(计算机断层扫描)和97%(淋巴造影)。然而,应强调计算机断层扫描的价值,因为它可以显示淋巴造影未显示的淋巴结,包括纵隔淋巴结,以及脾脏、肝脏和肺部的病变。