Lamoré P J, Verweij C, Brocaar M P
Audiology. 1984;23(5):453-66. doi: 10.3109/00206098409070085.
The test-retest variability of a series of auditory functions has been investigated in a group of severely hearing-impaired and deaf subjects (64 ears, median Fletcher index: 80 dB) and in a group of 10 controls with normal hearing. An adaptive forced-choice procedure was used for both groups. The functions were: tone audiogram, difference limen for intensity, difference limen for frequency, modulation transfer function and critical ratio. In spite of sometimes strongly deviating function values within the hearing-impaired group, the test-retest variability of the two groups was found to be of the same order of magnitude, except for the tone audiogram where the variability in the hearing-impaired group was twice that for the control group.
在一组重度听力受损和失聪受试者(64只耳朵,弗莱彻指数中位数:80分贝)以及一组10名听力正常的对照组中,对一系列听觉功能的重测变异性进行了研究。两组均采用自适应强制选择程序。这些功能包括:纯音听力图、强度辨别阈、频率辨别阈、调制传递函数和临界比率。尽管听力受损组内的功能值有时差异很大,但发现两组的重测变异性处于同一数量级,纯音听力图除外,听力受损组的变异性是对照组的两倍。