Fredberg J J, Keefe D H, Glass G M, Castile R G, Frantz I D
J Appl Physiol Respir Environ Exerc Physiol. 1984 Sep;57(3):788-800. doi: 10.1152/jappl.1984.57.3.788.
In six excised canine lungs, regional alveolar pressures (PA) were measured during small-amplitude high-frequency oscillations applied at the airway opening. Both the regional distribution of PA's and their relationship to pressure excursions at the airway opening (Pao) were assessed in terms of amplitude and phase. PA was sampled in several capsules glued to the pleural surface and communicating with alveolar gas via pleural punctures. Pao and PA were measured over the frequency (f) range 1-60 Hz, at transpulmonary pressures (PL) of 5, 10, and 25 cmH2O. The amplitude of PA excursions substantially exceeded Pao excursions at frequencies near the resonant frequency. At resonance the ratio [PA/Pao] was 1.9, 2.9, and 4.8 at PL's of 5, 10, and 25 cmH2O, respectively. Both spatial homogeneity and temporal synchrony of PA's between sampled lung regions decreased with f and increased with PL. Interregional variability of airway impedance [(Pao - PA)/Vao] and tissue impedance (PA/Vao) tended to be larger than differences due to changing PL but not as large as between-dog variability. These data define the baseline nonhomogeneity of the normal canine lung and also suggest that there may be some advantage in applying high-frequency ventilation at frequencies at least as high as lung resonant frequency.
在六个切除的犬肺中,在气道开口处施加小幅度高频振荡期间测量区域肺泡压力(PA)。根据幅度和相位评估PA的区域分布及其与气道开口处压力波动(Pao)的关系。PA在粘贴于胸膜表面并通过胸膜穿刺与肺泡气体相通的几个胶囊中进行采样。在1-60Hz的频率(f)范围内,在5、10和25cmH2O的跨肺压力(PL)下测量Pao和PA。在接近共振频率的频率下,PA波动的幅度大大超过Pao波动的幅度。在共振时,在PL为5、10和25cmH2O时,[PA/Pao]的比值分别为1.9、2.9和4.8。采样肺区域之间PA的空间均匀性和时间同步性均随f降低而随PL升高。气道阻抗[(Pao - PA)/Vao]和组织阻抗(PA/Vao)的区域间变异性往往大于因PL变化引起的差异,但不如犬之间的变异性大。这些数据定义了正常犬肺的基线非均匀性,也表明在至少与肺共振频率一样高的频率下应用高频通气可能有一些优势。