Briantais M J, Grangeot-Keros L, Pillot J
J Virol Methods. 1984 Aug;9(1):15-26. doi: 10.1016/0166-0934(84)90079-x.
The specificity and sensitivity of the IgM-capture immunoassay (IgM-CI) were evaluated for detection of rubella specific IgM and hepatitis B core (HBc) specific IgM. For rubella specific IgM, antibodies bound to the solid phase were detected by haemadsorption and for HBc specific IgM, by using HBc antigen (HBcAg) and radiolabelled IgG anti-HBc. Rheumatoid factor (RF) was found to interfere in the test for HBc specific IgM because IgM-RF bound to the solid phase reacted with aggregated radiolabelled HBc specific IgG. This false positive reaction did not occur when radiolabelled F(ab')2 was used instead of the whole IgG molecule. HBcAg purified from biological fluids might be coated with host IgG and under these conditions, HBcAg could react with RF. It was also demonstrated that high levels of IgG antibodies could interfere with IgG anti-mu coated-surface by means of non-immunological protein-protein interactions. In fact, IgG did not interfere in the rubella assay, whereas it did in the very sensitive anti-HBc test. To prevent this false-positive reaction, different dilution media were tested. Only the addition of non-specific IgG and fetal calf serum (FCS), to the dilution medium, seems to improve the specificity of the test. Furthermore, in order to decrease this non-specific IgG-IgG interaction and an occasional prozoning phenomenon, the dilution of serum to be tested was taken into account. Parameters considered to decrease sensitivity were also studied. RF, anti-F(ab')2 antibodies and non-specific IgM did not decrease significantly the sensitivity of the assay.
评估了IgM捕获免疫测定法(IgM-CI)检测风疹特异性IgM和乙肝核心(HBc)特异性IgM的特异性和敏感性。对于风疹特异性IgM,通过血细胞吸附检测结合到固相上的抗体;对于HBc特异性IgM,则使用HBc抗原(HBcAg)和放射性标记的抗HBc IgG进行检测。发现类风湿因子(RF)会干扰HBc特异性IgM的检测,因为结合到固相上的IgM-RF会与聚集的放射性标记HBc特异性IgG发生反应。当使用放射性标记的F(ab')2代替完整的IgG分子时,不会出现这种假阳性反应。从生物体液中纯化的HBcAg可能会被宿主IgG包被,在这种情况下,HBcAg会与RF发生反应。还证明了高水平的IgG抗体可通过非免疫性蛋白质-蛋白质相互作用干扰IgG抗μ包被表面。事实上,IgG不会干扰风疹检测,而在非常敏感的抗HBc检测中则会干扰。为防止这种假阳性反应,测试了不同的稀释介质。只有在稀释介质中添加非特异性IgG和胎牛血清(FCS)似乎能提高检测的特异性。此外,为了减少这种非特异性IgG-IgG相互作用和偶尔出现的前带现象,考虑了待测血清的稀释度。还研究了被认为会降低敏感性的参数。RF、抗F(ab')2抗体和非特异性IgM并未显著降低检测的敏感性。