Suppr超能文献

急性淋巴细胞白血病中免疫复合物的特征分析

Characterization of immune complexes in acute lymphoblastic leukaemia.

作者信息

Williams R C, Duncan M H, Tung K S, Stinson E R, Walker L C, Greaves M F

出版信息

Clin Exp Immunol. 1983 Nov;54(2):418-28.

Abstract

Sera from 120 children and young adults with acute leukaemia (59), various other tumours (53) and histiocytosis X (eight) were studied for the presence and characteristics of circulating immune complexes (CIC). Serial and parallel testing was performed using: C1q binding (solid phase), Raji cell radioimmunoassay and anti-C3 (solid phase). CIC were detected in 36 of 56 (64%) patients with acute lymphoblastic leukaemia (ALL) and in 62% of other tumour subjects. In the ALL sera, the mean positive C1q binding was 5.4 s.d., Raji cell 4.2 s.d. and anti-C3 4.4 s.d. In 12 ALL sera CIC were characterized for molecular size by sucrose gradient centrifugation. Most samples showed high molecular weight (19S) complexes but intermediate (11-14S) and smaller (8-9S) complexes were also detected. There was no apparent relationship between the presence, amount or physical size of the detectable CICs and clinical course of the patients studied; 12 patients with ALL in long term remission showed presence of CIC at some time during their course. Immune complexes precipitated from leukaemic sera were also examined for the presence of common ALL antigen (cALL) and Ia(DR) antigens utilizing rabbit antisera and mouse monoclonal antibodies. Experiments with isolated immune complexes from ALL sera provided no positive evidence for the presence of cALL antigen or Ia antigen within immune complex materials from ALL patients.

摘要

对120名患有急性白血病(59例)、各种其他肿瘤(53例)和组织细胞增多症X(8例)的儿童及青年的血清进行了循环免疫复合物(CIC)的存在情况及特征研究。采用以下方法进行系列和平行检测:C1q结合(固相法)、Raji细胞放射免疫测定法和抗C3(固相法)。在56例急性淋巴细胞白血病(ALL)患者中的36例(64%)以及62%的其他肿瘤患者中检测到了CIC。在ALL血清中,C1q结合阳性的平均值为5.4标准差,Raji细胞为4.2标准差,抗C3为4.4标准差。对12份ALL血清中的CIC进行了蔗糖梯度离心以确定其分子大小。大多数样本显示为高分子量(19S)复合物,但也检测到了中等分子量(11 - 14S)和较小分子量(8 - 9S)的复合物。所检测到的CIC的存在、数量或物理大小与所研究患者的临床病程之间没有明显关系;12例长期缓解的ALL患者在病程中的某些时候显示存在CIC。还利用兔抗血清和小鼠单克隆抗体检查了从白血病血清中沉淀出的免疫复合物中是否存在常见ALL抗原(cALL)和Ia(DR)抗原。对从ALL血清中分离出的免疫复合物进行的实验没有提供阳性证据表明ALL患者的免疫复合物材料中存在cALL抗原或Ia抗原。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ff00/1535870/d1e618e235d6/clinexpimmunol00152-0138-a.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验