Abstract

Elementary sensations of definable quality were evoked by intraneural electrical stimulation of sensory units through tungsten microelectrodes inserted in the median nerve of awake human subjects. The most commonly reported sensations were tapping, pressure, dull pain and sharp pain, which correlated with recording from RA units, SA I units, C nociceptors and A delta nociceptors, respectively. All sensations were projected more often to the fingertips than to the palm. The multifocal projections of sensations recruited by excitation of small groups of neighbouring nerve fibres were significantly more scattered in space than anticipated if these fibres had preserved an orderly intraneural map, implying lack of somatotopy in the nerve. Mean projected field sizes were 3.4 mm2 for sharp pain, 9.2 mm2 for tapping/vibration, 29.3 mm2 for pressure and 35.4 mm2 for dull pain, and in addition the latter two showed a rising size gradient from fingertip to palm. Consideration of projected field size as a variable in discriminative touch suggests that input from RA units and A delta nociceptors may be of importance in stimulus localization, while SA I units may play an additional role in two point discrimination.

摘要

通过插入清醒人类受试者正中神经的钨微电极对感觉单元进行神经内电刺激,可诱发具有可定义性质的基本感觉。最常报告的感觉是轻敲、压力、钝痛和刺痛,它们分别与记录到的快速适应(RA)单元、缓慢适应I型(SA I)单元、C类伤害感受器和Aδ类伤害感受器相关。所有感觉投射到指尖的频率比投射到手掌的频率更高。由相邻神经纤维小群兴奋所引发的感觉的多焦点投射在空间上的分散程度比这些纤维保持有序神经内图谱时预期的要显著得多,这意味着神经中缺乏躯体定位。刺痛的平均投射区域大小为3.4平方毫米,轻敲/振动为9.2平方毫米,压力为29.3平方毫米,钝痛为35.4平方毫米,此外,后两者从指尖到手掌呈现出大小递增的梯度。将投射区域大小视为辨别性触觉中的一个变量来考虑,表明来自RA单元和Aδ类伤害感受器的输入在刺激定位中可能很重要,而SA I单元可能在两点辨别中发挥额外作用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验