Seiple W, Price M J, Kupersmith M, Siegel I M, Carr R E
Ophthalmology. 1983 Sep;90(9):1127-32. doi: 10.1016/s0161-6420(83)80057-8.
Pattern evoked electroretinograms (PERG), diffuse flash electroretinograms (ERG) and visual evoked potentials were studied in patients with unilateral optic nerve disease. Patients with Snellen acuities of less than 6/30 did not have recordable PERGs in their affected eye, whereas their diffuse flash ERGs were normal. The VEPs were correspondingly reduced or absent when recorded from the poorer seeing eyes. A second group of patients with Snellen acuity between 6/6 and 6/30 in the involved eye showed reductions in the mean PERG amplitude of the affected as compared with the normal eyes. All affected eyes showed an abnormal contrast threshold measured with the PERG amplitude. Such results underscore the diagnostic value of the PERG in detecting even mildly affected cases of optic nerve disease.
对单侧视神经疾病患者进行了图形诱发视网膜电图(PERG)、弥漫性闪光视网膜电图(ERG)和视觉诱发电位研究。视力低于6/30的患者患眼无法记录到PERG,而其弥漫性闪光ERG正常。从视力较差的眼睛记录时,VEP相应降低或消失。第二组患眼视力在6/6至6/30之间的患者,与正常眼相比,患眼的平均PERG振幅降低。所有患眼用PERG振幅测量的对比阈值均异常。这些结果强调了PERG在检测即使是轻度视神经疾病病例中的诊断价值。