Evans J J, Legge M
J Endocrinol Invest. 1983 Oct;6(5):379-80. doi: 10.1007/BF03347620.
A comparison was made of estradiol in plasma and estrogen in urine of non-pregnant women. Estradiol was measured in plasma by RIA and estrogen excretion in urine was calculated from estrogen and creatine levels in early morning urine samples. There was a close correlation of values obtained by the two methods and both gave consistently low values for a woman who apparently did not ovulate. Either plasma or single urine specimens were convenient for the women and suitable for monitoring estrogen levels. These methods, which require only a single sample each day, would be especially useful when multiple samples are required.
对非孕期女性血浆中的雌二醇和尿液中的雌激素进行了比较。通过放射免疫分析法测定血浆中的雌二醇,并根据清晨尿液样本中的雌激素和肌酸水平计算尿液中的雌激素排泄量。两种方法所得结果密切相关,对于明显不排卵的女性,两者结果均持续偏低。血浆样本或单次尿液样本对女性来说都很方便,且适合监测雌激素水平。这些方法每天仅需一个样本,在需要多个样本时会特别有用。