The rate of clearance from blood of 111In-labelled heat damaged autologous erythrocytes (HD-RBC) has been compared with that of simultaneously injected autologous 99mTc-labelled erythrocytes (IgG-RBC) coated with a Rhesus anti-D antibody. In 17 studies, the number of antibody molecules coating the erythrocytes was 9000 (high coating) and in nine studies the number was 5000 (low coating). On gamma camera imaging, IgG-RBC uptake, at both levels of coating, could be visualized only in the spleen. HD-RBC were predominantly taken up by the spleen, although slight 111In activity was visible in the liver. The blood clearance of IgG-RBC was monoexponential, whereas that of HD-RBC was biexponential. The reciprocal of the t1/2 (the time taken for the 3 min value to fall by 50%) of the HD-RBC clearance correlated rather poorly with the rate constant of the simultaneous IgG-RBC clearance (r = 0.47, P greater than 0.05 at high coating; r = 0.75, P less than 0.05 at low coating). The rate constant of the second exponential of the HD-RBC clearance showed a correlation with the rate constant of IgG-RBC clearance that was closer than the reciprocal of the t1/2 of HD-RBC clearance (r = 0.89, P less than 0.001 at high coating; r = 0.76, P less than 0.05 at low coating) but significantly closer only at high coating. Splenic blood flow, measured using indium labelled platelets in ten subjects, correlated closely with the initial slope of HD-RBC clearance (r = 0.93, P less than 0.001).
已将铟 - 111标记的热损伤自体红细胞(HD - RBC)从血液中的清除率与同时注射的用恒河猴抗 - D抗体包被的自体锝 - 99m标记红细胞(IgG - RBC)的清除率进行了比较。在17项研究中,包被红细胞的抗体分子数量为9000(高包被),在9项研究中该数量为5000(低包被)。在γ相机成像中,在两种包被水平下,IgG - RBC的摄取仅在脾脏中可见。HD - RBC主要被脾脏摄取,尽管在肝脏中可见轻微的铟 - 111活性。IgG - RBC的血液清除呈单指数形式,而HD - RBC的清除呈双指数形式。HD - RBC清除的t1/2(3分钟值下降50%所需的时间)的倒数与同时进行的IgG - RBC清除的速率常数相关性较差(高包被时r = 0.47,P>0.05;低包被时r = 0.75,P<0.05)。HD - RBC清除的第二个指数的速率常数与IgG - RBC清除的速率常数的相关性比HD - RBC清除的t1/2的倒数更紧密(高包被时r = 0.89,P<0.001;低包被时r = 0.76,P<0.05),但仅在高包被时显著更紧密。在10名受试者中使用铟标记的血小板测量的脾血流量与HD - RBC清除的初始斜率密切相关(r = 0.93,P<0.001)。