Schneider R M, Jaszczak R J, Coleman R E, Cobb F R
J Nucl Med. 1984 Jul;25(7):747-54.
This study evaluates the potential effects of regional hypokinesis on measurements of global ejection fraction (EF) as determined by radionuclide angiographic techniques. Studies were performed in a two-compartment left-ventricular (LV) model that allowed stimulation of global, anterior-region, or posterior-region hypokinesis in a torso chamber with heart-to-background activity similar to that in clinical studies. Radionuclide techniques accurately measured changes in EF during global hypokinesis but progressively underestimated true EF during increasing anterior-region hypokinesis, and progressively overestimated true EF during increasing posterior hypokinesis. When EF (y-axis) was plotted against true EF (x-axis) for a 240-ml model, from linear regression equations, the slopes and intercepts were significantly different for anterior and posterior hypokinesis. The disproportionate effects of regional hypokinesis increased with LV size. Accurate EF was computed during regional hypokinesis by determining absolute LV volumes from count rates corrected for attenuation, depth, background activity and blood-pool activity. Thus, the disproportionate effects of regional hypokinesis on EF were corrected by considering differential count attenuation.
本研究评估了局部运动减弱对通过放射性核素血管造影技术测定的整体射血分数(EF)测量值的潜在影响。研究在一个双腔左心室(LV)模型中进行,该模型能够在体腔内模拟整体、前壁区域或后壁区域的运动减弱,其心脏与本底活性与临床研究相似。放射性核素技术在整体运动减弱期间能准确测量EF的变化,但在前壁区域运动减弱增加时逐渐低估真实EF,而后壁运动减弱增加时逐渐高估真实EF。对于一个240毫升的模型,当将EF(纵坐标)与真实EF(横坐标)作图时,根据线性回归方程,前壁和后壁运动减弱的斜率和截距显著不同。局部运动减弱的不成比例影响随左心室大小增加而增大。通过根据针对衰减、深度、本底活性和血池活性校正后的计数率确定绝对左心室容积,可在局部运动减弱期间计算出准确的EF。因此,通过考虑不同的计数衰减,校正了局部运动减弱对EF的不成比例影响。