Vision Res. 1984;24(5):409-15. doi: 10.1016/0042-6989(84)90039-7.

Abstract

A knowledge of the refractive index distribution within the crystalline lens is necessary to define the optical properties of the eye. This report describes the first nondestructive method for measuring the refractive index of intact crystalline lenses based on the work of Chu (1977) [Electron Lett. 13, 736-738] and Barrell and Pask (1978) [Opt. Commun. 27, 230-234] for optical fibre preforms. The method is simpler and more accurate than previous methods and shows that the rat crystalline lens has a smooth and almost parabolic distribution of refractive index.

摘要

了解晶状体内部的折射率分布对于确定眼睛的光学特性至关重要。本报告基于Chu(1977年)[《电子学快报》13, 736 - 738]以及Barrell和Pask(1978年)[《光学通信》27, 230 - 234]关于光纤预制棒的研究成果,描述了第一种用于测量完整晶状体折射率的无损方法。该方法比之前的方法更简单、更精确,且表明大鼠晶状体的折射率分布平滑且近乎呈抛物线状。